Abstract

Background Globally we face a projected shortage of 11 million healthcare practitioners by 2030, and administrative burden consumes 50% of clinical time. Artificial intelligence (AI) has the potential to help alleviate these problems. However, no end-to-end autonomous large language model (LLM)-based AI system has been rigorously evaluated in real-world clinical practice. In this study, we evaluated whether a multi-agent LLM-based AI framework can function autonomously as an AI doctor in a virtual urgent care setting.

Methods We retrospectively compared the performance of the multi-agent AI system Doctronic and board-certified clinicians across 500 consecutive urgent-care telehealth encounters. The primary end points: diagnostic concordance, treatment plan consistency, and safety metrics, were assessed by blinded LLM-based adjudication and expert human review.

Results The top diagnosis of Doctronic and clinician matched in 81% of cases, and the treatment plan aligned in 99.2% of cases. No clinical hallucinations occurred (e.g., diagnosis or treatment not supported by clinical findings). In an expert review of discordant cases, AI performance was superior in 36.1%, and human performance was superior in 9.3%; the diagnoses were equivalent in the remaining cases.

Conclusions In this first large-scale validation of an autonomous AI doctor, we demonstrated strong diagnostic and treatment plan concordance with human clinicians. These findings indicate that multi-agent AI systems can achieve comparable clinical decision-making to human providers and offer a potential solution to healthcare workforce shortages.

FigureCompeting Interest Statement

All authors are equity owners of Doctronic Inc.

Funding Statement

This study did not receive any funding

Author Declarations

I confirm all relevant ethical guidelines have been followed, and any necessary IRB and/or ethics committee approvals have been obtained.

Yes

The details of the IRB/oversight body that provided approval or exemption for the research described are given below:

Ethics committee of Doctronic Research Group gave ethical approval for this work. The work was deemed to utilize only de-identified and unlinked data from an EHR for the study.

I confirm that all necessary patient/participant consent has been obtained and the appropriate institutional forms have been archived, and that any patient/participant/sample identifiers included were not known to anyone (e.g., hospital staff, patients or participants themselves) outside the research group so cannot be used to identify individuals.

Yes

I understand that all clinical trials and any other prospective interventional studies must be registered with an ICMJE-approved registry, such as ClinicalTrials.gov. I confirm that any such study reported in the manuscript has been registered and the trial registration ID is provided (note: if posting a prospective study registered retrospectively, please provide a statement in the trial ID field explaining why the study was not registered in advance).

Yes

I have followed all appropriate research reporting guidelines, such as any relevant EQUATOR Network research reporting checklist(s) and other pertinent material, if applicable.

Yes

Data Availability