{"id":325719,"date":"2025-12-04T22:14:12","date_gmt":"2025-12-04T22:14:12","guid":{"rendered":"https:\/\/www.newsbeep.com\/ca\/325719\/"},"modified":"2025-12-04T22:14:12","modified_gmt":"2025-12-04T22:14:12","slug":"geometry-induced-spin-chirality-in-a-non-chiral-ferromagnet-at-zero-field","status":"publish","type":"post","link":"https:\/\/www.newsbeep.com\/ca\/325719\/","title":{"rendered":"Geometry-induced spin chirality in a non-chiral ferromagnet at zero field"},"content":{"rendered":"<p>Sample preparation<\/p>\n<p>The magnetic chiral tubes were fabricated by combining TPL and ALD. We applied the additive manufacturing methodology described in ref. <a data-track=\"click\" data-track-action=\"reference anchor\" data-track-label=\"link\" data-test=\"citation-ref\" aria-label=\"Reference 31\" title=\"Guo, H., Deenen, A. J. M., Xu, M., Hamdi, M. &amp; Grundler, D. Realization and control of bulk and surface modes in 3D nanomagnonic networks by additive manufacturing of ferromagnets. Adv. Mater. 35, 2303292 (2023).\" href=\"http:\/\/www.nature.com\/articles\/s41565-025-02055-3#ref-CR31\" id=\"ref-link-section-d60008067e2617\" rel=\"nofollow noopener\" target=\"_blank\">31<\/a> to 3D polymer wires that contained helical reliefs. These were prepared by TPL using a Photonic Professional GT+ system (Nanoscribe) in three steps. First, negative photoresist IP-Dip was dropped onto a fused-silica substrate (25\u2009\u00d7\u200925\u2009mm2, 0.7\u2009mm thick). Second, an infrared femtosecond laser (wavelength, 780\u2009nm; power, 20\u2009mW) was focused inside the resist exploiting the dip-in laser lithography configuration for the exposure. Third, the whole substrate was immersed in propylene glycol monomethyl ether acetate for 20\u2009min and isopropyl alcohol for another 5\u2009min. After the polymer had been dried in ambient conditions, the sample was put into a hot-wall Beneq TFS200 ALD system. We conformally coated the polymer with a 30-nm-thick nickel shell after depositing 5-nm-thick Al2O3 using the plasma-enhanced ALD process presented in ref. <a data-track=\"click\" data-track-action=\"reference anchor\" data-track-label=\"link\" data-test=\"citation-ref\" aria-label=\"Reference 28\" title=\"Salazar-Cardona, M. M. et al. Nonreciprocity of spin waves in magnetic nanotubes with helical equilibrium magnetization. Appl. Phys. Lett. 118, 262411 (2021).\" href=\"http:\/\/www.nature.com\/articles\/s41565-025-02055-3#ref-CR28\" id=\"ref-link-section-d60008067e2627\" rel=\"nofollow noopener\" target=\"_blank\">28<\/a>. The detailed preparation process is presented in Supplementary Fig. <a data-track=\"click\" data-track-label=\"link\" data-track-action=\"supplementary material anchor\" href=\"http:\/\/www.nature.com\/articles\/s41565-025-02055-3#MOESM1\" rel=\"nofollow noopener\" target=\"_blank\">1<\/a>.<\/p>\n<p>BLS<\/p>\n<p>The spin dynamics were investigated by \u00b5BLS at room temperature (Supplementary Fig. <a data-track=\"click\" data-track-label=\"link\" data-track-action=\"supplementary material anchor\" href=\"http:\/\/www.nature.com\/articles\/s41565-025-02055-3#MOESM1\" rel=\"nofollow noopener\" target=\"_blank\">2<\/a>). The samples were mounted on a piezo stage, which allowed movement in steps of 50\u2009nm underneath the laser focus. Positive and negative external magnetic fields were applied by permanent magnets mounted in different orientations along the x axis, with the ACMs positioned parallel to the x axis. A green laser (wavelength, 532\u2009nm) with a power of 3\u2009mW was focused on the surface of the helical magnet using a 100\u00d7 objective lens with a numerical aperture of 0.75. The full-width at half-maximum of the focused laser spot was experimentally determined to have an upper bound of 436\u2009nm (Supplementary Fig. <a data-track=\"click\" data-track-label=\"link\" data-track-action=\"supplementary material anchor\" href=\"http:\/\/www.nature.com\/articles\/s41565-025-02055-3#MOESM1\" rel=\"nofollow noopener\" target=\"_blank\">15<\/a>). The s-polarized component of the scattered light was passed through a Glan\u2013Taylor polarizer and directed to a six-pass tandem Fabry\u2013Perot interferometer. In the \u00b5BLS set-up, the focused laser light produced a cone of incidence angles around the optical axis of the lens. The backscattered light contained photons that interacted with magnons having different in-plane wavevectors +k and \u2013k, with k magnitudes ranging from 0 to \u223c17.7\u2009rad\u2009\u00b5m\u22121.<\/p>\n<p>XMCD images<\/p>\n<p>Magnetic chiral tubes of right-handedness (Extended Data Fig. <a data-track=\"click\" data-track-label=\"link\" data-track-action=\"figure anchor\" href=\"http:\/\/www.nature.com\/articles\/s41565-025-02055-3#Fig5\" rel=\"nofollow noopener\" target=\"_blank\">1a<\/a>) and left-handedness (Extended Data Fig. <a data-track=\"click\" data-track-label=\"link\" data-track-action=\"figure anchor\" href=\"http:\/\/www.nature.com\/articles\/s41565-025-02055-3#Fig5\" rel=\"nofollow noopener\" target=\"_blank\">1d<\/a>) were fabricated on a silicon nitride window membrane. This scaffold supports the ACMs, suspending them over empty space by their ends. These structures were imaged using scanning transmission X-ray microscopy at the UE46_MAXYMUS endstation<a data-track=\"click\" data-track-action=\"reference anchor\" data-track-label=\"link\" data-test=\"citation-ref\" aria-label=\"Reference 42\" title=\"Weigand, M. et al. TimeMaxyne: a shot-noise limited, time-resolved pump-and-probe acquisition system capable of 50 GHz frequencies for synchrotron-based X-ray microscopy. Crystals 12, 1029 (2022).\" href=\"http:\/\/www.nature.com\/articles\/s41565-025-02055-3#ref-CR42\" id=\"ref-link-section-d60008067e2681\" rel=\"nofollow noopener\" target=\"_blank\">42<\/a> of the BESSY II electron storage ring operated by the Helmholtz-Zentrum Berlin f\u00fcr Materialien und Energie. We performed measurements in multibunch hybrid operating mode, where the sample is illuminated by X-rays stroboscopically at a repetition frequency of 500\u2009MHz. We acquired static transmission images using circular polarized monochromatic X-rays with left- and right-handed circularities at the nickel L3 absorption edge (854.5\u2009eV). This energy, slightly offset from the absorption maximum, was chosen to optimize the XMCD signal while minimizing signal loss caused by the thickness of the structures. To remove artificial intensity offsets caused by occasional noise artefacts inherent in the measurement technique (such as the detection of zeroth-order diffracted light, electronic noise from the circuits or thermal fluctuations in the electronics), we applied a dark-field correction to all the transmission images as follows:<\/p>\n<p>$${I}_{\\mathrm{corrected}}=\\frac{{I}_{\\mathrm{sample}}-D}{{I}_{\\mathrm{vacuum}}-D}$$<\/p>\n<p>where D represents the dark-field factor, which can have values between 0 and 1. For our transmission images, a dark-field factor between 0.9 and 0.92 was applied<a data-track=\"click\" data-track-action=\"reference anchor\" data-track-label=\"link\" data-test=\"citation-ref\" aria-label=\"Reference 43\" title=\"Wirtensohn, S. et al. Nanoscale dark-field imaging in full-field transmission X-ray microscopy. Optica 11, 852 (2024).\" href=\"http:\/\/www.nature.com\/articles\/s41565-025-02055-3#ref-CR43\" id=\"ref-link-section-d60008067e2742\" rel=\"nofollow noopener\" target=\"_blank\">43<\/a>.<\/p>\n<p>We transformed the transmission images into a dimensionless logarithm scale of normalized intensity, ln(Inorm), using the equation:<\/p>\n<p>$$\\mathrm{ln}\\left({I}_{\\mathrm{norm}}\\right)=\\mathrm{ln}\\left(\\frac{{I}_{\\mathrm{measured}}}{{I}_{0}}\\right)=-\\mu t$$<\/p>\n<p>where Imeasured is the intensity of the transmission images measured, I0 is the reference intensity in the empty space, \u00b5 is the absorption coefficient (which depends on the circularity of the light) and t is the material thickness. To qualitatively determine the relative direction of the magnetization with respect to the X-ray wavevector k, we calculated the XMCD factor in each point of the measured transmission images:<\/p>\n<p>$$\\mathrm{XMCD}\\,\\mathrm{factor}\\propto {\\mu }^{-}-{\\mu }^{+}.$$<\/p>\n<p>The resulting XMCD images were processed with a Gaussian filter, using \u03c3 = 0.5 pixels. This approach gives us estimates of the azimuthal magnetic orientation.<\/p>\n<p>We imaged both RH and LH ACMs using a measurement configuration where the X-rays are incident normally on the structure\u2019s main axis along the \\(\\hat{z}\\) direction. This measuring set-up provided sensitivity to the out-of-plane component of the magnetic configuration. The results for the RH ACM (Extended Data Fig. <a data-track=\"click\" data-track-label=\"link\" data-track-action=\"figure anchor\" href=\"http:\/\/www.nature.com\/articles\/s41565-025-02055-3#Fig5\" rel=\"nofollow noopener\" target=\"_blank\">1a,b<\/a>), discussed in the main text, reveal that the remanent azimuthal magnetic orientation is determined by the gyration direction of the helix (Extended Data Fig. <a data-track=\"click\" data-track-label=\"link\" data-track-action=\"figure anchor\" href=\"http:\/\/www.nature.com\/articles\/s41565-025-02055-3#Fig5\" rel=\"nofollow noopener\" target=\"_blank\">1c<\/a>). A similar behaviour is observed for the LH ACM: the transmission image corresponds to the red-highlighted region in Extended Data Fig. <a data-track=\"click\" data-track-label=\"link\" data-track-action=\"figure anchor\" href=\"http:\/\/www.nature.com\/articles\/s41565-025-02055-3#Fig5\" rel=\"nofollow noopener\" target=\"_blank\">1d<\/a>, showing both tubular and helical regions of the ACM (Extended Data Fig. <a data-track=\"click\" data-track-label=\"link\" data-track-action=\"figure anchor\" href=\"http:\/\/www.nature.com\/articles\/s41565-025-02055-3#Fig5\" rel=\"nofollow noopener\" target=\"_blank\">1e<\/a>).<\/p>\n<p>XMCD images of the remanent state, measured at \u00b50H\u2009=\u2009\u00b10\u2009mT, show an azimuthally oriented out-of-plane component. As with the RH ACM, this results in a contrast reversal with the direction of the saturating field, confirming that the azimuthal orientation is determined by the helix gyration direction (Extended Data Fig. <a data-track=\"click\" data-track-label=\"link\" data-track-action=\"figure anchor\" href=\"http:\/\/www.nature.com\/articles\/s41565-025-02055-3#Fig5\" rel=\"nofollow noopener\" target=\"_blank\">1f<\/a>). When we compare XMCD results for the RH and LH ACMs, we observe that both exhibit similar magnetic patterns but with opposite contrast, indicating that the gyration is reversed between RH and LH ACMs. This implies that the handedness of the magnetic texture is intrinsically determined by the structural chirality of the ACM.<\/p>\n<p>To further understand how the helix direction imprints the gyration direction of the magnetic texture, we present schematics illustrating the X-ray detector view and the projection of the magnetization along the X-ray wavevector view (Supplementary Fig. <a data-track=\"click\" data-track-label=\"link\" data-track-action=\"supplementary material anchor\" href=\"http:\/\/www.nature.com\/articles\/s41565-025-02055-3#MOESM1\" rel=\"nofollow noopener\" target=\"_blank\">3<\/a>). In the RH ACM, the helix gyration produces a counterclockwise texture for \u00b50H\u2009=\u2009+0\u2009mT (Supplementary Fig. <a data-track=\"click\" data-track-label=\"link\" data-track-action=\"supplementary material anchor\" href=\"http:\/\/www.nature.com\/articles\/s41565-025-02055-3#MOESM1\" rel=\"nofollow noopener\" target=\"_blank\">3a<\/a>) and a clockwise texture for \u00b50H\u2009=\u2009\u22120\u2009mT (Supplementary Fig. <a data-track=\"click\" data-track-label=\"link\" data-track-action=\"supplementary material anchor\" href=\"http:\/\/www.nature.com\/articles\/s41565-025-02055-3#MOESM1\" rel=\"nofollow noopener\" target=\"_blank\">3b<\/a>). The opposite occurs in the LH ACM, where a clockwise texture is generated with \u00b50H\u2009=\u2009+0\u2009mT (Supplementary Fig. <a data-track=\"click\" data-track-label=\"link\" data-track-action=\"supplementary material anchor\" href=\"http:\/\/www.nature.com\/articles\/s41565-025-02055-3#MOESM1\" rel=\"nofollow noopener\" target=\"_blank\">3c<\/a>) and a counterclockwise texture with \u00b50H\u2009=\u2009\u22120\u2009mT (Supplementary Fig. <a data-track=\"click\" data-track-label=\"link\" data-track-action=\"supplementary material anchor\" href=\"http:\/\/www.nature.com\/articles\/s41565-025-02055-3#MOESM1\" rel=\"nofollow noopener\" target=\"_blank\">3d<\/a>). Thus, the contrast observed in the XMCD images in Extended Fig. <a data-track=\"click\" data-track-label=\"link\" data-track-action=\"figure anchor\" href=\"http:\/\/www.nature.com\/articles\/s41565-025-02055-3#Fig5\" rel=\"nofollow noopener\" target=\"_blank\">1<\/a> can be explained by the relative projection of the magnetization along the X-ray wavevector, where white contrast appears when the projection is parallel to k, and black contrast appears when it is antiparallel.<\/p>\n<p>Simulation<\/p>\n<p>Micromagnetic simulations were conducted using MuMax3 software<a data-track=\"click\" data-track-action=\"reference anchor\" data-track-label=\"link\" data-test=\"citation-ref\" aria-label=\"Reference 44\" title=\"Vansteenkiste, A. et al. The design and verification of MuMax3. AIP Adv. 4, 107133 (2014).\" href=\"http:\/\/www.nature.com\/articles\/s41565-025-02055-3#ref-CR44\" id=\"ref-link-section-d60008067e2988\" rel=\"nofollow noopener\" target=\"_blank\">44<\/a>, which solves the Landau\u2013Lifshitz\u2013Gilbert equation on a finite difference grid. We considered a nickel ACM consisting of a tube with inner radius of 220\u2009nm and a thickness of 30\u2009nm which intersects a hollow helix of ellipsoidal cross-section. The helix had a pitch of 2,000\u2009nm, a diameter of 740\u2009nm, cross-sectional inner major and minor radii of 120\u2009nm and 70\u2009nm, respectively, and a thickness of 30\u2009nm. The helix and tubular segment are directly connected to each other (Supplementary Fig. <a data-track=\"click\" data-track-label=\"link\" data-track-action=\"supplementary material anchor\" href=\"http:\/\/www.nature.com\/articles\/s41565-025-02055-3#MOESM1\" rel=\"nofollow noopener\" target=\"_blank\">5b<\/a>), and are coupled via both exchange and magnetostatic interactions. The saturation magnetization was set to Ms\u2009=\u2009490\u2009kA\u2009m\u22121 and the exchange stiffness to Aexc\u2009=\u20098\u2009pJ\u2009m\u22121 (ref. <a data-track=\"click\" data-track-action=\"reference anchor\" data-track-label=\"link\" data-test=\"citation-ref\" aria-label=\"Reference 45\" title=\"Coey, J. M. D. Magnetism and Magnetic Materials (Cambridge Univ. Press, 2010).\" href=\"http:\/\/www.nature.com\/articles\/s41565-025-02055-3#ref-CR45\" id=\"ref-link-section-d60008067e3008\" rel=\"nofollow noopener\" target=\"_blank\">45<\/a>). The system was discretized into 160\u2009\u00d7\u2009160\u2009\u00d7\u2009384 cells of dimension 5\u2009\u00d7\u20095\u2009\u00d7\u20095.2\u2009nm3. Six repetitions of periodic boundary conditions along the z direction were used.<\/p>\n<p>Hysteresis diagrams of the structures were computed by sweeping an applied field parallel to the tube axis with a 2\u00b0 misalignment between +1\u2009T and \u22121\u2009T and back to +1\u2009T. Additionally, a constant background field of 0.7\u2009mT along the x,y diagonal was applied. The magnetic ground state was computed in between specified field increments by first using the steepest conjugate gradient method<a data-track=\"click\" data-track-action=\"reference anchor\" data-track-label=\"link\" data-test=\"citation-ref\" aria-label=\"Reference 46\" title=\"Exl, L. et al. LaBonte&#039;s method revisited: an effective steepest descent method for micromagnetic energy minimization. J. Appl. Phys. 115, 17D118 (2014).\" href=\"http:\/\/www.nature.com\/articles\/s41565-025-02055-3#ref-CR46\" id=\"ref-link-section-d60008067e3026\" rel=\"nofollow noopener\" target=\"_blank\">46<\/a> to minimize the energy and then solving the Landau\u2013Lifshitz\u2013Gilbert equation without a precessional term. The resulting ground states provided the initial state for the computation of the toroidal moment and the dynamic behaviour.<\/p>\n<p>The toroidal moment for a given magnetization distribution \\({{m}}_{0}({\\mathbf{r}})\\) was computed per layer according to:<\/p>\n<p>$${\\mathbf{\\uptau }}\\left({{m}}_{0}\\right)\\mathop{=}\\limits^{\\text{def}}\\frac{1}{A}{\\iint }_{A}{\\rm{d}}x{\\rm{d}}y{\\mathbf{r}}\\times {{m}}_{0}({\\mathbf{r}})$$<\/p>\n<p>with r the position vector using the tube axis as the origin and A is the area.<\/p>\n<p>The dynamic simulations were conducted as follows. A dynamic field \\(h={h}_{0}{\\mathrm{sinc}}\\left(2{{\\uppi}}{f}_{{\\rm{c}}}\\left(t-{t}_{\\mathrm{delay}}\\right)\\right)\\) was confined to a strip of width 20\u2009nm along the longitudinal axis of the tube in the centre of the ACM. Here, we used the amplitude h0 = 3 mT, the cut-off frequency fc = 15 GHz and the time offset tdelay = 26.7 ns. The strip covered only half the cross-sectional area of the ACM to excite both odd- and even-numbered m modes. The dynamic field was applied perpendicular to the tube axis. The simulations were run for a total time of 53.3\u2009ns and the magnetization was sampled on the surface of the tube along the tube axis every 33.3\u2009ps. The damping was set to \u03b1 = 10\u22123 and increased quadratically to 1 near the ends of the structure. The dispersion shown in Fig. <a data-track=\"click\" data-track-label=\"link\" data-track-action=\"figure anchor\" href=\"http:\/\/www.nature.com\/articles\/s41565-025-02055-3#Fig4\" rel=\"nofollow noopener\" target=\"_blank\">4b,d<\/a> was obtained by performing a 2D fast Fourier transform over the dynamic magnetization sampled on the tube along the z axis.<\/p>\n<p>Analytical dispersion<\/p>\n<p>The simulated dispersion in Fig. <a data-track=\"click\" data-track-label=\"link\" data-track-action=\"figure anchor\" href=\"http:\/\/www.nature.com\/articles\/s41565-025-02055-3#Fig4\" rel=\"nofollow noopener\" target=\"_blank\">4c,d<\/a> is plotted together with data obtained from the analytical model proposed by Salazar-Cardona et al.<a data-track=\"click\" data-track-action=\"reference anchor\" data-track-label=\"link\" data-test=\"citation-ref\" aria-label=\"Reference 28\" title=\"Salazar-Cardona, M. M. et al. Nonreciprocity of spin waves in magnetic nanotubes with helical equilibrium magnetization. Appl. Phys. Lett. 118, 262411 (2021).\" href=\"http:\/\/www.nature.com\/articles\/s41565-025-02055-3#ref-CR28\" id=\"ref-link-section-d60008067e3321\" rel=\"nofollow noopener\" target=\"_blank\">28<\/a> for nanotubes with helical equilibrium magnetization. The analytical dispersion is given by<\/p>\n<p>$${\\omega }_{m}({\\mathbf{k}})={\\omega }_{M}\\left[{{\\mathscr{A}}}_{m}({\\mathbf{k}})+\\sqrt{{{\\mathscr{B}}}_{m}(k){C}_{m}({\\mathbf{k}})}\\right]$$<\/p>\n<p>with \\({\\omega }_{M}=\\gamma {\\mu }_{0}{M}_{{\\rm{s}}}\\), \u03b3 is the gyromagnetic ratio and k the wavevector. The index m denotes the azimuthal mode. \\({{\\mathscr{A}}}_{m}({\\mathbf{k}}),{{\\mathscr{B}}}_{m}({\\mathbf{k}}),{C}_{m}({\\mathbf{k}})\\) are the dynamic stiffness fields. The frequency non-reciprocity is determined by the magnetochiral stiffness field \\({{\\mathscr{A}}}_{m}({\\mathbf{k}})=\\)\\(-\\chi {\\mathscr{K}}(m,{\\mathbf{k}})\\sin \\left(\\theta \\right)+p(N(m,{\\mathbf{k}})-\\frac{2m{\\lambda }_{\\mathrm{exc}}^{2}}{{b}^{2}})\\cos \\left(\\theta \\right)\\). Here, \u03b8 is the angle of the magnetization with respect to the tube axis, b is the geometrical factor depending on the radius, \u03bbexc is the exchange length, p = \u00b11 is the polarity of the magnetization and \u03c7 = \u00b11 is the helicity (<a data-track=\"click\" data-track-label=\"link\" data-track-action=\"supplementary material anchor\" href=\"http:\/\/www.nature.com\/articles\/s41565-025-02055-3#MOESM1\" rel=\"nofollow noopener\" target=\"_blank\">Supplementary Text<\/a>). The functions \\({\\mathscr{K}}(m,{\\mathbf{k}}),{\\mathscr{N}}\\left(m,{\\mathbf{k}}_{z}\\right)\\) are demagnetizing factors and depend only on the geometry. The analytical data shown in Fig. <a data-track=\"click\" data-track-label=\"link\" data-track-action=\"figure anchor\" href=\"http:\/\/www.nature.com\/articles\/s41565-025-02055-3#Fig4\" rel=\"nofollow noopener\" target=\"_blank\">4c,d<\/a> are obtained from equation (18) (<a data-track=\"click\" data-track-label=\"link\" data-track-action=\"supplementary material anchor\" href=\"http:\/\/www.nature.com\/articles\/s41565-025-02055-3#MOESM1\" rel=\"nofollow noopener\" target=\"_blank\">Supplementary Text<\/a>) in the thin-shell approximation where t \u2248 \u03bbexc, with t the thickness \u03bbexc. The frequency non-reciprocity sweeps shown in Fig. <a data-track=\"click\" data-track-label=\"link\" data-track-action=\"figure anchor\" href=\"http:\/\/www.nature.com\/articles\/s41565-025-02055-3#Fig4\" rel=\"nofollow noopener\" target=\"_blank\">4e\u2013g<\/a> were computed based on equation (18) (<a data-track=\"click\" data-track-label=\"link\" data-track-action=\"supplementary material anchor\" href=\"http:\/\/www.nature.com\/articles\/s41565-025-02055-3#MOESM1\" rel=\"nofollow noopener\" target=\"_blank\">Supplementary Text<\/a>) in the ultrathin-shell approximation where \\(t\\approx {\\lambda }_{\\mathrm{exc}}\\ll r\\) and r is the mean radius of the tube. In all other cases, the dispersion was computed in the thin-shell limit. For the tube sizes under consideration, the two approximations were in good agreement for small values (\u227210\u2009rad\u2009\u03bcm\u22121) of kz. Complete expressions for the dispersion in both approximations are given in <a data-track=\"click\" data-track-label=\"link\" data-track-action=\"supplementary material anchor\" href=\"http:\/\/www.nature.com\/articles\/s41565-025-02055-3#MOESM1\" rel=\"nofollow noopener\" target=\"_blank\">Supplementary Text<\/a>.<\/p>\n<p>The magnetic parameters used for the analytical calculations on nickel are identical to those of the simulations. The thickness of the tube was set to 30\u2009nm. A good quantitative agreement between the analytical theory and the simulations was achieved using an effective mean radius of r\u2009=\u2009300\u2009nm and a magnetization angle of \u03b8\u2009=\u200920\u00b0 (Supplementary Fig. <a data-track=\"click\" data-track-label=\"link\" data-track-action=\"supplementary material anchor\" href=\"http:\/\/www.nature.com\/articles\/s41565-025-02055-3#MOESM1\" rel=\"nofollow noopener\" target=\"_blank\">8<\/a>) in the analytical model. Note that this effective radius is larger than the mean radius of the simulated tubular region (235\u2009nm). However, the corresponding mean diameter used for the analytical calculations (600\u2009nm) is almost identical to the cross-sectional mean major-diameter of the ACM (590\u2009nm), that is, the maximum distance between opposing sides along a cross-section of the ACM (Supplementary Fig. <a data-track=\"click\" data-track-label=\"link\" data-track-action=\"supplementary material anchor\" href=\"http:\/\/www.nature.com\/articles\/s41565-025-02055-3#MOESM1\" rel=\"nofollow noopener\" target=\"_blank\">5b<\/a>). For the computations on permalloy in Fig. <a data-track=\"click\" data-track-label=\"link\" data-track-action=\"figure anchor\" href=\"http:\/\/www.nature.com\/articles\/s41565-025-02055-3#Fig4\" rel=\"nofollow noopener\" target=\"_blank\">4f,g<\/a>, we used magnetic parameters Ms\u2009=\u2009800\u2009kA\u2009m\u22121 and Aexc\u2009=\u200913\u2009pJ\u2009m\u22121.<\/p>\n","protected":false},"excerpt":{"rendered":"Sample preparation The magnetic chiral tubes were fabricated by combining TPL and ALD. We applied the additive manufacturing&hellip;\n","protected":false},"author":2,"featured_media":325720,"comment_status":"","ping_status":"","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[24],"tags":[49,48,3673,91867,3882,3676,3677,3678,314,66,2281],"class_list":{"0":"post-325719","1":"post","2":"type-post","3":"status-publish","4":"format-standard","5":"has-post-thumbnail","7":"category-physics","8":"tag-ca","9":"tag-canada","10":"tag-general","11":"tag-magnetic-devices","12":"tag-magnetic-properties-and-materials","13":"tag-materials-science","14":"tag-nanotechnology","15":"tag-nanotechnology-and-microengineering","16":"tag-physics","17":"tag-science","18":"tag-spintronics"},"_links":{"self":[{"href":"https:\/\/www.newsbeep.com\/ca\/wp-json\/wp\/v2\/posts\/325719","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.newsbeep.com\/ca\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.newsbeep.com\/ca\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.newsbeep.com\/ca\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/www.newsbeep.com\/ca\/wp-json\/wp\/v2\/comments?post=325719"}],"version-history":[{"count":0,"href":"https:\/\/www.newsbeep.com\/ca\/wp-json\/wp\/v2\/posts\/325719\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.newsbeep.com\/ca\/wp-json\/wp\/v2\/media\/325720"}],"wp:attachment":[{"href":"https:\/\/www.newsbeep.com\/ca\/wp-json\/wp\/v2\/media?parent=325719"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.newsbeep.com\/ca\/wp-json\/wp\/v2\/categories?post=325719"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.newsbeep.com\/ca\/wp-json\/wp\/v2\/tags?post=325719"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}