{"id":791618,"date":"2026-07-10T00:00:19","date_gmt":"2026-07-10T00:00:19","guid":{"rendered":"https:\/\/www.newsbeep.com\/ca\/791618\/"},"modified":"2026-07-10T00:00:19","modified_gmt":"2026-07-10T00:00:19","slug":"keeping-cool-how-meta-plans-to-cut-down-on-water-use-at-its-alberta-data-centre","status":"publish","type":"post","link":"https:\/\/www.newsbeep.com\/ca\/791618\/","title":{"rendered":"Keeping cool: How Meta plans to cut down on water use at its\u00a0Alberta\u00a0data centre"},"content":{"rendered":"<p>A Meta Platforms Inc. executive garnered applause at a news conference this week after he boasted that a gargantuan data centre planned for north of Edmonton would use less water annually than a typical\u00a0Alberta\u00a0golf course.\u00a0<\/p>\n<p>The tech behemoth was announcing a $13-billion-plus investment in a complex the size of 33 Canadian Football League fields. It will be powered by a new natural gas plant that could eventually produce more electricity than what the City of Edmonton uses.\u00a0<\/p>\n<p>The data centre in Sturgeon County, like other hyperscale proposals in Canada, is to use what\u2019s known as a closed-loop cooling system to keep servers from overheating. That differs from an evaporative cooling system, which requires enormous amounts of cool water that is not reused.\u00a0<\/p>\n<p>Gary Demasi, vice-president of data centre strategy and development at Meta, told a news conference Wednesday that no water will be needed for regular cooling operations. \u00a0\u00a0<\/p>\n<p>\u201cThe onsite water use is limited to domestic uses, fire protection systems and some equipment maintenance applications,\u201d he said.\u00a0<\/p>\n<p>Marina Freire-Gormaly, an associate professor of mechanical engineering at York University, said the closed-loop technique works well in cooler climates like Alberta\u2019s. Data centres in hotter places tend to use evaporative cooling because there\u2019s not as much of a temperature difference between the equipment inside and the air outside.\u00a0<\/p>\n<p>Meta would likely use a coolant similar to the fluids used in vehicles, which would run through pipes overtop of the hottest parts of the chips and absorb the heat, she said. The loop would then run to the outside of the building, where the air is cooler, and a series of fans would move the heat away. The cooled-down fluid would head back to the servers.<\/p>\n<p>Freire-Gormaly said the closed-loop system would work best in the winter and she\u2019s curious how Meta\u2019s designs would account for how hot it can sometimes get in the Edmonton area during the summer.\u00a0<\/p>\n<p>A recent blog post from AI chipmaker Nvidia, one of Wall Street\u2019s most valuable names, said its latest servers can use coolant that\u2019s not so cool at all: up to 45 C, which is more sweltering than a hot tub. The fluid exits the server rack at 55 C.\u00a0<\/p>\n<p>Nvidia said that cooling alone has historically accounted for up to 40 per cent of a data centre\u2019s electricity consumption, so its ability to use higher-temperature coolant marks a great efficiency leap. The coolant Nvidia uses is three-quarters water, one-quarter propylene glycol.<\/p>\n<p>\u201cThese newer data centres, they should always use closed-loop cooling,\u201d Freire-Gormaly said.<\/p>\n<p>\u201cThese evaporative cooling approaches are really harmful to the environment. And the reason they\u2019re relying on it is because they don\u2019t have that natural temperature difference between the environment and the temperature that they\u2019re trying to cool from.\u201d<\/p>\n<p>For that reason, she sees how Canada can be an attractive location for hyperscalers like Meta to set up shop.\u00a0<\/p>\n<p>\u201cBut I think it\u2019s also important that we realize what power source we\u2019re using.\u201d<\/p>\n<p>It\u2019s not clear what kind of cooling system the adjacent power plant will have and if that component will have its own hefty water footprint, Freire-Gormaly said.\u00a0<\/p>\n<p>Freire-Gormaly also wonders if the companies might consider ways to use the data centre\u2019s waste heat.\u00a0<\/p>\n<p>\u201cWhy not use that waste heat for things like warming buildings or having a secondary heat transfer loop?\u201d<\/p>\n<p>A study led by University of Cambridge researchers earlier this year looked at what they call the \u201cheat island effect\u201d in areas surrounding AI data centres. The study estimates the land surface temperature increases by an average of 2 C after the start of operations. It found that some increase in temperature could be detected up to 10 kilometres away.\u00a0<\/p>\n<p>Researchers at York University\u2019s Schulich School of Business have been mapping Canada\u2019s emerging data centre landscape. In paper, currently under review at a peer reviewed journal, they say that as of June of this year, there were 194 data centres operating with a combined capacity of 1.6 gigawatts.<\/p>\n<p>That\u2019s dwarfed by those announced or under construction \u2014 213 planned, accounting for more than 22 gigawatts.\u00a0<\/p>\n<p>And\u00a0Alberta\u00a0is at the epicentre.\u00a0<\/p>\n<p>That province accounts for 92 per cent of planned new capacity, while it represents 10 per cent of facilities currently active.\u00a0<\/p>\n<p>\u201cClearly there is something going on there that\u2019s attracting that development,\u201d said Lyndsey Rolheiser, an assistant professor of urban and real estate economics who co-authored the paper with Alexander Carlo.<\/p>\n<p>\u201cAlberta\u00a0is not pursuing big taxpayer-funded incentives. They\u2019re relying on their deregulated self-generation energy market to really bring these providers in and that seems to be working.\u201d<\/p>\n<p>Because there\u2019s currently insufficient grid capacity,\u00a0Alberta\u00a0is prioritizing projects that contract or build their own power sources, which have virtually all been from natural gas.\u00a0<\/p>\n<p>Many residents are operating in \u201cinformation vacuums\u201d so the province needs to be prepared to encounter some backlash and communicate exactly what it\u2019s doing to ensure the appropriate environmental and safety protections are in place, Rolheiser said. \u00a0<\/p>\n<p>Ali Bayat, a professor of civil and environmental engineering at the University of\u00a0Alberta, said the province is well-positioned to meet data centre demand from a workforce perspective. Meta has said it expects 3,000 jobs during construction.\u00a0<\/p>\n<p>\u201cWe have an industrial province,\u201d he said. \u201cThere is capacity in this province for that line of construction work.\u00a0Alberta\u00a0is unique in that regard.\u201d<\/p>\n<p>This report by The Canadian Press was first published July 9, 2026.<\/p>\n<p>\t\tKeep it Factual<\/p>\n<p>Add CityNews Edmonton as a trusted source on Google to see more local stories from us.<\/p>\n<p>\t\t<a href=\"https:\/\/www.google.com\/preferences\/source?q=edmonton.citynews.ca\" rel=\"nofollow noopener\" target=\"_blank\"><br \/>\n\t\t<img loading=\"lazy\" decoding=\"async\" class=\"add-trusted-source-badge\" src=\"https:\/\/www.newsbeep.com\/ca\/wp-content\/uploads\/2026\/05\/1778178555_824_google-trusted-badge.png\" alt=\"Add as a preferred source on Google\" width=\"198\" height=\"63\"\/><br \/>\n\t\t<\/a><\/p>\n","protected":false},"excerpt":{"rendered":"A Meta Platforms Inc. executive garnered applause at a news conference this week after he boasted that a&hellip;\n","protected":false},"author":2,"featured_media":791619,"comment_status":"","ping_status":"","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[194294],"tags":[49,48,23752],"class_list":["post-791618","post","type-post","status-publish","format-standard","has-post-thumbnail","category-edmonton","tag-ca","tag-canada","tag-edmonton"],"_links":{"self":[{"href":"https:\/\/www.newsbeep.com\/ca\/wp-json\/wp\/v2\/posts\/791618","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.newsbeep.com\/ca\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.newsbeep.com\/ca\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.newsbeep.com\/ca\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/www.newsbeep.com\/ca\/wp-json\/wp\/v2\/comments?post=791618"}],"version-history":[{"count":0,"href":"https:\/\/www.newsbeep.com\/ca\/wp-json\/wp\/v2\/posts\/791618\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.newsbeep.com\/ca\/wp-json\/wp\/v2\/media\/791619"}],"wp:attachment":[{"href":"https:\/\/www.newsbeep.com\/ca\/wp-json\/wp\/v2\/media?parent=791618"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.newsbeep.com\/ca\/wp-json\/wp\/v2\/categories?post=791618"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.newsbeep.com\/ca\/wp-json\/wp\/v2\/tags?post=791618"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}