{"id":657390,"date":"2026-10-17T08:36:21","date_gmt":"2026-10-17T08:36:21","guid":{"rendered":"https:\/\/www.newsbeep.com\/ie\/657390\/"},"modified":"2026-10-17T08:36:21","modified_gmt":"2026-10-17T08:36:21","slug":"directional-magnetic-field-detection-with-zero-bias-surface-acoustic-wave-sensors","status":"publish","type":"post","link":"https:\/\/www.newsbeep.com\/ie\/657390\/","title":{"rendered":"Directional magnetic field detection with zero-bias surface acoustic wave sensors"},"content":{"rendered":"<p>To verify that the intended magnetic anisotropies were successfully imprinted during layer growth, the integral magnetization of both sensor designs was measured using an inductive BH-loop tracer. Figure <a data-track=\"click\" data-track-label=\"link\" data-track-action=\"figure anchor\" href=\"http:\/\/www.nature.com\/articles\/s41598-026-76696-2#Fig4\" rel=\"nofollow noopener\" target=\"_blank\">4<\/a>a and b show the magnetization loops for the scissor-like and parallel-and-canted configurations, respectively. The combined magnetic easy axis and magnetic hard axis responses of the magnetic stack are shown in blue and red. For each measurement direction, the magnetization signal is measured parallel to the applied field and perpendicular to it, by switching by switching the orientation of the pick-up coil relative to the applied field and sample orientation. The component parallel to the applied field, corresponding to a cosine projection of the magnetization vector, is plotted as solid lines, while the perpendicular sine component is represented by dashed lines. This decomposition allows investigation of the underlying magnetization reversal process. In the case of reversible coherent rotation, the magnetization rotates continuously as a rigid vector, so that \\(\\:M\\:\\left|\\right|\\:H\\) and \\(\\:M\\perp\\:H\\) trace smooth, hysteresis-free curves. In contrast, reversal mediated by domain nucleation and domain-wall motion is irreversible and typically displays a finite hysteresis. In particular, measuring different courses of the transverse component along the hard axis is expected. For a single macrospin like behavior undergoing coherent magnetic rotation, the transverse magnetization reaches a maximum at remanence, whereas for a multi-domain state or related non macrospin behavior, the contributions from oppositely oriented domains may compensate, resulting in a reduced net transverse magnetization<a data-track=\"click\" data-track-action=\"reference anchor\" data-track-label=\"link\" data-test=\"citation-ref\" aria-label=\"Reference 21\" title=\"McCord, J., Sch&#xE4;fer, R., Mattheis, R. &amp; Barholz, K. U. Kerr observations of asymmetric magnetization reversal processes in CoFe\/IrMn bilayer systems. J. Appl. Phys.93, 5491&#x2013;5497 (2003).\" href=\"http:\/\/www.nature.com\/articles\/s41598-026-76696-2#ref-CR21\" id=\"ref-link-section-d75329341e1115\" rel=\"nofollow noopener\" target=\"_blank\">21<\/a>,<a data-track=\"click\" data-track-action=\"reference anchor\" data-track-label=\"link\" data-test=\"citation-ref\" aria-label=\"Reference 22\" title=\"Jovi&#x10D;evi&#x107; Klug, M. et al. Antiparallel exchange biased multilayers for low magnetic noise magnetic field sensors. Applied Phys. Letters114, 192410 (2019).\" href=\"http:\/\/www.nature.com\/articles\/s41598-026-76696-2#ref-CR22\" id=\"ref-link-section-d75329341e1118\" rel=\"nofollow noopener\" target=\"_blank\">22<\/a>. The effective anisotropy directions of each magnetic stack were determined by identifying the effective hard axis direction. These measurements reveal that the imprinted anisotropies during deposition exhibit slight angular offsets with respect to the intended directions for both sensor designs. For the scissor-like configuration, the effective anisotropy directions are rotated by 10\u00b0 relative to the delay line. For the parallel-and-canted sensor, the extracted angle amounts to 14\u00b0, instead of the targeted 10\u00b0. These deviations in the direction of anisotropy likely arise from the interplay of unidirectional exchange-bias and stress-induced anisotropy<a data-track=\"click\" data-track-action=\"reference anchor\" data-track-label=\"link\" data-test=\"citation-ref\" aria-label=\"Reference 16\" title=\"Schell, V. et al. Magnetic anisotropy controlled FeCoSiB thin films for surface acoustic wave magnetic field sensors. Applied Phys. Letters116, 073503 (2020).\" href=\"http:\/\/www.nature.com\/articles\/s41598-026-76696-2#ref-CR16\" id=\"ref-link-section-d75329341e1122\" rel=\"nofollow noopener\" target=\"_blank\">16<\/a>. Moreover, a non-collinear, tilted alignment of unidirectional anisotropy may occur in exchange-biased samples, including top-pinned MnIr-based layers<a data-track=\"click\" data-track-action=\"reference anchor\" data-track-label=\"link\" data-test=\"citation-ref\" aria-label=\"Reference 23\" title=\"McCord, J., Hamann, C., Sch&#xE4;fer, R., Schultz, L. &amp; Mattheis, R. Nonlinear exchange coupling and magnetic domain asymmetry in ferromagnetic\/IrMn thin films. Phys. Rev. B. 78, 94419 (2008).\" href=\"http:\/\/www.nature.com\/articles\/s41598-026-76696-2#ref-CR23\" id=\"ref-link-section-d75329341e1127\" rel=\"nofollow noopener\" target=\"_blank\">23<\/a>,<a data-track=\"click\" data-track-action=\"reference anchor\" data-track-label=\"link\" data-test=\"citation-ref\" aria-label=\"Reference 24\" title=\"Chung, S. H., Hoffmann, A. &amp; Grimsditch, M. Interplay between exchange bias and uniaxial anisotropy in a ferromagnetic\/antiferromagnetic exchange-coupled system. Phys. Rev. B. 71, 214430 (2005).\" href=\"http:\/\/www.nature.com\/articles\/s41598-026-76696-2#ref-CR24\" id=\"ref-link-section-d75329341e1130\" rel=\"nofollow noopener\" target=\"_blank\">24<\/a>. In addition, minor temporal changes in the magnetic properties due to training effects of the exchange-bias may contribute to the observed offsets<a data-track=\"click\" data-track-action=\"reference anchor\" data-track-label=\"link\" data-test=\"citation-ref\" aria-label=\"Reference 25\" title=\"Binek, C. Training of the exchange-bias effect: A simple analytic approach. Phys Rev. B70, 014421 (2004).\" href=\"http:\/\/www.nature.com\/articles\/s41598-026-76696-2#ref-CR25\" id=\"ref-link-section-d75329341e1134\" rel=\"nofollow noopener\" target=\"_blank\">25<\/a>. Also, the effective anisotropy directions of the individual layers within the scissor stack can be resolved. When the applied field is aligned parallel to the effective easy axis of an individual layer, the sine component vanishes, since magnetization reversal occurs just along the anisotropy direction, leaving no transverse magnetization contribution. The resulting alignments of the effective anisotropy directions \\(\\:{K}_{\\text{e}\\text{f}\\text{f}}\\) of the individual layers are displayed in Fig. <a data-track=\"click\" data-track-label=\"link\" data-track-action=\"figure anchor\" href=\"http:\/\/www.nature.com\/articles\/s41598-026-76696-2#Fig4\" rel=\"nofollow noopener\" target=\"_blank\">4<\/a>c and d, respectively.<\/p>\n<p>Fig. 4<img decoding=\"async\" aria-describedby=\"figure-4-desc\" src=\"https:\/\/www.newsbeep.com\/ie\/wp-content\/uploads\/2026\/10\/41598_2026_76696_Fig4_HTML.png\" alt=\"Fig. 4\" loading=\"lazy\" width=\"685\" height=\"246\"\/><\/p>\n<p>Hysteresis loops measured with a BH-loop tracer for (a) scissor-like alignment and (b) parallel &amp; canted alignment. The blue curves correspond to the combined easy axis of the full stack and the red curves to the hard axis. The signal is divided in cosine (full line) and sine (dashed line) fraction of the magnetization. (c) Shows the deduced anisotropy directions \\(\\:\\rm{K}_{eff}\\) aligned along 20\u00b0 and 180\u00b0 for the two magnetic layer stacks for the scissor-like configuration. (d) For the parallel &amp; canted configuration the effective anisotropy direction is aligned at 14\u00b0.<\/p>\n<p>In Fig. <a data-track=\"click\" data-track-label=\"link\" data-track-action=\"figure anchor\" href=\"http:\/\/www.nature.com\/articles\/s41598-026-76696-2#Fig4\" rel=\"nofollow noopener\" target=\"_blank\">4<\/a>a two well-separated hysteresis loops are observed (blue full curve), when a magnetic field is applied along 10\u00b0, the direction of the combined easy axis. This phenomenon is due to the presence of two exchange-biased magnetic layers whose effective anisotropies point in nearly opposite directions for the scissor-like design. At remanence, the loop exhibits a finite sine component of the magnetization (dashed line). While the applied field is aligned along the combined easy axis at 10\u00b0, the individual layer easy axes are oriented at 20\u00b0 and 180\u00b0. For low magnetic fields, the magnetization aligns collinearly with the respective \\(\\:\\rm{K}_{eff}\\) of each layer. This results in a signal with twice the amplitude of the sine component of \\(\\:M\\), arising from the perpendicular contributions of both layers. When the field reaches \u00b1 1.5 mT, the magnetization of one layer switches, leading to cancellation of the sine components. Along the hard axis (\\(\\:H\\) || 100\u00b0), a finite remanent magnetization exists and the magnetizations of the two layers rotate coherently<a data-track=\"click\" data-track-action=\"reference anchor\" data-track-label=\"link\" data-test=\"citation-ref\" aria-label=\"Reference 22\" title=\"Jovi&#x10D;evi&#x107; Klug, M. et al. Antiparallel exchange biased multilayers for low magnetic noise magnetic field sensors. Applied Phys. Letters114, 192410 (2019).\" href=\"http:\/\/www.nature.com\/articles\/s41598-026-76696-2#ref-CR22\" id=\"ref-link-section-d75329341e1209\" rel=\"nofollow noopener\" target=\"_blank\">22<\/a>. The absence of a net transverse magnetization component in the corresponding dashed curve indicates that the two layers undergo coherent rotation in opposite directions, consistent with the intended scissor state.\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0<\/p>\n<p>In Fig. <a data-track=\"click\" data-track-label=\"link\" data-track-action=\"figure anchor\" href=\"http:\/\/www.nature.com\/articles\/s41598-026-76696-2#Fig4\" rel=\"nofollow noopener\" target=\"_blank\">4<\/a>b, the parallel-and-canted sensor exhibits a single hysteresis loop along easy axis, characteristic for single exchange-biased magnetic layers. The loop is shifted to approximately \u2212 0.6 mT. The perpendicular magnetization component vanishes at the effective hard axis angle (blue dashed curve), while a perpendicular field orientation (red dashed curve) produces the maximum response. The latter indicates that the magnetizations in both layers undergo coherent rotation in the same direction<a data-track=\"click\" data-track-action=\"reference anchor\" data-track-label=\"link\" data-test=\"citation-ref\" aria-label=\"Reference 22\" title=\"Jovi&#x10D;evi&#x107; Klug, M. et al. Antiparallel exchange biased multilayers for low magnetic noise magnetic field sensors. Applied Phys. Letters114, 192410 (2019).\" href=\"http:\/\/www.nature.com\/articles\/s41598-026-76696-2#ref-CR22\" id=\"ref-link-section-d75329341e1219\" rel=\"nofollow noopener\" target=\"_blank\">22<\/a> and suggests a single-domain magnetic state during magnetization-reversal for magnetic field applied along (\\(\\:H\\) || 104\u00b0). Additional investigations of the magnetic domain configurations by large field-of-view magneto-optical Kerr effect (MOKE) microscopy<a data-track=\"click\" data-track-action=\"reference anchor\" data-track-label=\"link\" data-test=\"citation-ref\" aria-label=\"Reference 26\" title=\"McCord, J. Progress in magnetic domain observation by advanced magneto-optical microscopy. J. Phys. D: Appl. Phys.48, 333001 (2015).\" href=\"http:\/\/www.nature.com\/articles\/s41598-026-76696-2#ref-CR26\" id=\"ref-link-section-d75329341e1229\" rel=\"nofollow noopener\" target=\"_blank\">26<\/a> are provided in the Supplementary Information.<\/p>\n<p>Figure\u00a0<a data-track=\"click\" data-track-label=\"link\" data-track-action=\"figure anchor\" href=\"http:\/\/www.nature.com\/articles\/s41598-026-76696-2#Fig5\" rel=\"nofollow noopener\" target=\"_blank\">5<\/a> summarizes the readout characteristics of the SAW magnetic field sensors, excited with 0 dBm. Figure\u00a0<a data-track=\"click\" data-track-label=\"link\" data-track-action=\"figure anchor\" href=\"http:\/\/www.nature.com\/articles\/s41598-026-76696-2#Fig5\" rel=\"nofollow noopener\" target=\"_blank\">5<\/a>a\u2013c refer to the scissor-like alignment, while 4d\u2013f show the results for the parallel-and-canted alignment. Figure\u00a0<a data-track=\"click\" data-track-label=\"link\" data-track-action=\"figure anchor\" href=\"http:\/\/www.nature.com\/articles\/s41598-026-76696-2#Fig5\" rel=\"nofollow noopener\" target=\"_blank\">5<\/a>a and d show the magnetic sensitivity when an AC magnetic field is applied at a perpendicular angle (90\u00b0) to the direction of SAW propagation, with a peak-to-peak field of 10 \u00b5T at 10\u00a0Hz. For the scissor-like alignment, the sensitivity at zero magnetic field amounts to (488\u2009\u00b1\u200910) \u00b0\/mT. The sensitivity can be further enhanced, visible by the two distinct maxima at approximately 0.17 mT with 562 \u00b0\/mT and 0.96 mT with 739 \u00b0\/mT. In contrast, the parallel-and-canted configuration exhibits higher sensitivity maxima at 0.33 mT with 800 \u00b0\/mT and 1.05 mT with 1006 \u00b0\/mT, while the zero-field sensitivity is comparable at (490\u2009\u00b1\u200910) \u00b0\/mT. Since none of the sensitivity maxima occur exactly at \\(\\:{\\mu\\:}_{0}H\\) = 0 mT, the ideal magnetization states sketched in Fig.\u00a0<a data-track=\"click\" data-track-label=\"link\" data-track-action=\"figure anchor\" href=\"http:\/\/www.nature.com\/articles\/s41598-026-76696-2#Fig3\" rel=\"nofollow noopener\" target=\"_blank\">3<\/a>b and c are not fully achieved, which is consistent with the angular offsets extracted from the BH-loop tracer measurements. Because of the coherent rotation of magnetization, only a very small hysteresis is visible in the insets of the sensitivity curves.<\/p>\n<p>Fig. 5<img decoding=\"async\" aria-describedby=\"figure-5-desc\" src=\"https:\/\/www.newsbeep.com\/ie\/wp-content\/uploads\/2026\/10\/41598_2026_76696_Fig5_HTML.png\" alt=\"Fig. 5\" loading=\"lazy\" width=\"685\" height=\"885\"\/><\/p>\n<p>Electrical sensor characterization for different magnetic alignments. Blue and red curves correspond to measurements after negative and positive field saturation, respectively. All measurements were taken at 0 dBm. Plots a\u2013c) show the scissor-like alignment, while plots d\u2013f) show the parallel-and-canted alignment. a, d) Sensitivity as a function of applied field, with an inset highlighting the range\u2009\u00b1\u20090.3 mT. b, e) Phase noise measured as an average over nine runs, with shaded areas indicating\u2009\u00b1\u20091 standard deviation. c, f) Resulting LOD calculated from the sensitivity and phase noise data.<\/p>\n<p>Figure <a data-track=\"click\" data-track-label=\"link\" data-track-action=\"figure anchor\" href=\"http:\/\/www.nature.com\/articles\/s41598-026-76696-2#Fig5\" rel=\"nofollow noopener\" target=\"_blank\">5<\/a>b and e show the phase noise spectra of the sensors. Nine individual measurements were performed each after saturating the sensors in positive and negative magnetic field directions. From these data, an average phase noise and the corresponding standard deviation were calculated. The final noise measurements were carried out without any externally applied magnetic bias field. The phase noise spectrum exhibits the characteristic 1\/f frequency dependence at offset frequencies up to 104 Hz, above which the frequency-independent thermal noise floor becomes dominant<a data-track=\"click\" data-track-action=\"reference anchor\" data-track-label=\"link\" data-test=\"citation-ref\" aria-label=\"Reference 27\" title=\"Durdaut, P. et al. Phase Noise of SAW Delay Line Magnetic Field Sensors. Sensors21, 5631 (2021).\" href=\"http:\/\/www.nature.com\/articles\/s41598-026-76696-2#ref-CR27\" id=\"ref-link-section-d75329341e1295\" rel=\"nofollow noopener\" target=\"_blank\">27<\/a>. At a frequency of 10 Hz, the phase noise ranges between \u2212 122 dBrad\u00b2\/Hz and \u2212 124 dBrad\u00b2\/Hz for both sensor concepts. These values are approximately 5\u20137 dB lower than those reported for SAW sensors with antiparallel exchange-bias published by Schell et al.<a data-track=\"click\" data-track-action=\"reference anchor\" data-track-label=\"link\" data-test=\"citation-ref\" aria-label=\"Reference 13\" title=\"Schell, V. et al. Exchange biased surface acoustic wave magnetic field sensors. Sci. Rep.13, 8446 (2023).\" href=\"http:\/\/www.nature.com\/articles\/s41598-026-76696-2#ref-CR13\" id=\"ref-link-section-d75329341e1299\" rel=\"nofollow noopener\" target=\"_blank\">13<\/a>. The lower noise level is consistent with the reduced sensitivity of the present sensors<a data-track=\"click\" data-track-action=\"reference anchor\" data-track-label=\"link\" data-test=\"citation-ref\" aria-label=\"Reference 27\" title=\"Durdaut, P. et al. Phase Noise of SAW Delay Line Magnetic Field Sensors. Sensors21, 5631 (2021).\" href=\"http:\/\/www.nature.com\/articles\/s41598-026-76696-2#ref-CR27\" id=\"ref-link-section-d75329341e1303\" rel=\"nofollow noopener\" target=\"_blank\">27<\/a>. Since phase noise scales with sensitivity, the higher sensitivity reported by Schell et al.<a data-track=\"click\" data-track-action=\"reference anchor\" data-track-label=\"link\" data-test=\"citation-ref\" aria-label=\"Reference 13\" title=\"Schell, V. et al. Exchange biased surface acoustic wave magnetic field sensors. Sci. Rep.13, 8446 (2023).\" href=\"http:\/\/www.nature.com\/articles\/s41598-026-76696-2#ref-CR13\" id=\"ref-link-section-d75329341e1308\" rel=\"nofollow noopener\" target=\"_blank\">13<\/a> corresponds to a higher noise level of their sensor. It is also advantageous that no external bias field is applied during the noise measurement, as the bias field generation might add further noise. The generally low phase noise can be attributed to the domain state stabilized by the exchange-bias, which reduces the phase noise by about 7 dB compared to a multidomain thin film<a data-track=\"click\" data-track-action=\"reference anchor\" data-track-label=\"link\" data-test=\"citation-ref\" aria-label=\"Reference 13\" title=\"Schell, V. et al. Exchange biased surface acoustic wave magnetic field sensors. Sci. Rep.13, 8446 (2023).\" href=\"http:\/\/www.nature.com\/articles\/s41598-026-76696-2#ref-CR13\" id=\"ref-link-section-d75329341e1312\" rel=\"nofollow noopener\" target=\"_blank\">13<\/a>,<a data-track=\"click\" data-track-action=\"reference anchor\" data-track-label=\"link\" data-test=\"citation-ref\" aria-label=\"Reference 16\" title=\"Schell, V. et al. Magnetic anisotropy controlled FeCoSiB thin films for surface acoustic wave magnetic field sensors. Applied Phys. Letters116, 073503 (2020).\" href=\"http:\/\/www.nature.com\/articles\/s41598-026-76696-2#ref-CR16\" id=\"ref-link-section-d75329341e1315\" rel=\"nofollow noopener\" target=\"_blank\">16<\/a>. Only a small difference between the phase noise spectra measured after positive and negative saturation is observed, indicating only slightly different magnetic configurations. This observation is consistent with the remaining minor hysteresis seen in both the BH-loop tracer measurements and the sensitivity curves.<\/p>\n<p>Figure <a data-track=\"click\" data-track-label=\"link\" data-track-action=\"figure anchor\" href=\"http:\/\/www.nature.com\/articles\/s41598-026-76696-2#Fig5\" rel=\"nofollow noopener\" target=\"_blank\">5<\/a>c and f present the calculated LOD, obtained by dividing the phase noise by the sensitivity. For the scissor-like alignment, a LOD of (77 \u00b1 4) pT\/Hz1\/2 after negative saturation and (84 \u00b1 3) pT\/Hz1\/2 after positive saturation is achieved. The parallel-and-canted configuration yields (69 \u00b1 8) pT\/Hz1\/2 after positive saturation and (85 \u00b1 11) pT\/Hz1\/2 for the opposite saturation direction. To the best of the authors\u2019 knowledge, these values represent the best LOD reported so far for SAW magnetic field sensors operated without an external bias field. Table <a data-track=\"click\" data-track-label=\"link\" data-track-action=\"table anchor\" href=\"http:\/\/www.nature.com\/articles\/s41598-026-76696-2#Tab1\" rel=\"nofollow noopener\" target=\"_blank\">1<\/a> summarizes the performance of previously reported SAW magnetic field sensors. Notably, while state-of-the-art SAW sensors employing external bias fields have reported LOD values that are 50\u201360 pT\/Hz1\/2 lower<a data-track=\"click\" data-track-action=\"reference anchor\" data-track-label=\"link\" data-test=\"citation-ref\" aria-label=\"Reference 13\" title=\"Schell, V. et al. Exchange biased surface acoustic wave magnetic field sensors. Sci. Rep.13, 8446 (2023).\" href=\"http:\/\/www.nature.com\/articles\/s41598-026-76696-2#ref-CR13\" id=\"ref-link-section-d75329341e1339\" rel=\"nofollow noopener\" target=\"_blank\">13<\/a>, the present results are obtained without an external bias field. Promising approaches to further improve the SAW sensors presented include enhanced angular control of the anisotropy, optimization of the SAW excitation power, and an increase in magnetic volume via repeated multilayer stacks<a data-track=\"click\" data-track-action=\"reference anchor\" data-track-label=\"link\" data-test=\"citation-ref\" aria-label=\"Reference 28\" title=\"Kittmann, A. et al. Sensitivity and noise analysis of SAW magnetic field sensors with varied magnetostrictive layer thicknesses. Sens. Actuators A: Phys.311, 111998 (2020).\" href=\"http:\/\/www.nature.com\/articles\/s41598-026-76696-2#ref-CR28\" id=\"ref-link-section-d75329341e1343\" rel=\"nofollow noopener\" target=\"_blank\">28<\/a>. The scissor-like configuration provides a clear advantage for LOD improvement. Owing to the opposing orientation of the anisotropy axes, magnetic flux can close internally between the two exchange-biased layers. This reduces stray field energy and prevents the formation of magnetic domains at the film edges<a data-track=\"click\" data-track-action=\"reference anchor\" data-track-label=\"link\" data-test=\"citation-ref\" aria-label=\"Reference 13\" title=\"Schell, V. et al. Exchange biased surface acoustic wave magnetic field sensors. Sci. Rep.13, 8446 (2023).\" href=\"http:\/\/www.nature.com\/articles\/s41598-026-76696-2#ref-CR13\" id=\"ref-link-section-d75329341e1347\" rel=\"nofollow noopener\" target=\"_blank\">13<\/a>,<a data-track=\"click\" data-track-action=\"reference anchor\" data-track-label=\"link\" data-test=\"citation-ref\" aria-label=\"Reference 22\" title=\"Jovi&#x10D;evi&#x107; Klug, M. et al. Antiparallel exchange biased multilayers for low magnetic noise magnetic field sensors. Applied Phys. Letters114, 192410 (2019).\" href=\"http:\/\/www.nature.com\/articles\/s41598-026-76696-2#ref-CR22\" id=\"ref-link-section-d75329341e1350\" rel=\"nofollow noopener\" target=\"_blank\">22<\/a>,<a data-track=\"click\" data-track-action=\"reference anchor\" data-track-label=\"link\" data-test=\"citation-ref\" aria-label=\"Reference 29\" title=\"Frommberger, M., McCord, J. &amp; Quandt, E. Crossed anisotropy magnetic cores for integrated inductors. J. Magn. Magn. Mater.290&#x2013;291, 1487&#x2013;1490 (2005).\" href=\"http:\/\/www.nature.com\/articles\/s41598-026-76696-2#ref-CR29\" id=\"ref-link-section-d75329341e1353\" rel=\"nofollow noopener\" target=\"_blank\">29<\/a>. This behavior is confirmed by the MOKE images shown in the Supplementary Information, where the scissor configuration exhibits a stable single-domain state across the entire thin film. This stabilization advantage should be maintained for additional repetitions of the multilayer stack.<\/p>\n<p>Table 1 Comparison of the scissor-like anisotropy SAW magnetic field sensor with previously reported SAW-based magnetic field sensors.<\/p>\n<p>Furthermore, the directional dependence of the SAW sensor sensitivity is investigated. For this purpose, the sensors are placed between a pair of Helmholtz coils generating a sinusoidal magnetic field. The in-plane AC magnetic field sensitivity is then measured while rotating the sensor over 360\u00b0 under zero external bias conditions.<\/p>\n<p>Fig. 6<img decoding=\"async\" aria-describedby=\"figure-6-desc\" src=\"https:\/\/www.newsbeep.com\/ie\/wp-content\/uploads\/2026\/10\/41598_2026_76696_Fig6_HTML.png\" alt=\"Fig. 6\" loading=\"lazy\" width=\"685\" height=\"319\"\/><\/p>\n<p>Directionality of the sensitivity with no artificial DC magnetic bias field in a 10 \u00b5T, 10\u00a0Hz AC magnetic field. Angular reference system as introduced in Fig.\u00a0<a data-track=\"click\" data-track-label=\"link\" data-track-action=\"figure anchor\" href=\"http:\/\/www.nature.com\/articles\/s41598-026-76696-2#Fig3\" rel=\"nofollow noopener\" target=\"_blank\">3<\/a>a. Fitting the data by a |sin| function calculates an 11\u00b0 angular offset for the scissor-like anisotropy a), and an 8\u00b0 offset for the parallel &amp; canted alignment b).<\/p>\n<p>The resulting polar plots for both the scissor-like and the parallel-and-canted configurations (Fig. <a data-track=\"click\" data-track-label=\"link\" data-track-action=\"figure anchor\" href=\"http:\/\/www.nature.com\/articles\/s41598-026-76696-2#Fig6\" rel=\"nofollow noopener\" target=\"_blank\">6<\/a>a, b) exhibit a twofold symmetric angular dependence in a figure-of-eight pattern, which has been also reported for SAW sensors exhibiting a single magnetic layer with uniaxial anisotropy by Hu et al. <a data-track=\"click\" data-track-action=\"reference anchor\" data-track-label=\"link\" data-test=\"citation-ref\" aria-label=\"Reference 18\" title=\"Hu, W., Huang, M., Xie, H., Zhang, H. &amp; Bai, F. Self-Biased Magnetic Field Sensors Based on Surface Acoustic Waves through Angle-Dependent Magnetoacoustic Coupling. Phys Rev. Applied19, 014010 (2023).\" href=\"http:\/\/www.nature.com\/articles\/s41598-026-76696-2#ref-CR18\" id=\"ref-link-section-d75329341e1686\" rel=\"nofollow noopener\" target=\"_blank\">18<\/a>. Displayed in red in Fig. <a data-track=\"click\" data-track-label=\"link\" data-track-action=\"figure anchor\" href=\"http:\/\/www.nature.com\/articles\/s41598-026-76696-2#Fig6\" rel=\"nofollow noopener\" target=\"_blank\">6<\/a>, a |sin| function is fitted to the measured data. The fit reveals an angular shift of 11\u00b0 for the scissor-like configuration and 8\u00b0 for the parallel-and-canted anisotropy configuration. Using the same model introduced in the first section, the maximum sensitivity of the parallel-and-canted configuration with an anisotropy tilt of 14\u00b0 (as obtained from the BH-loop tracer) is expected to occur at \u2248 8\u00b0. This prediction is in good agreement with the angular shift obtained from the |sin| fit and further highlights the micromagnetic aspects in determining the directional response and sensitivity of SAW magnetic field sensors. In the scissor-like configuration B-H loop tracer measurements in Fig. <a data-track=\"click\" data-track-label=\"link\" data-track-action=\"figure anchor\" href=\"http:\/\/www.nature.com\/articles\/s41598-026-76696-2#Fig4\" rel=\"nofollow noopener\" target=\"_blank\">4<\/a>a reveal that the magnetization directions are non-collinear in remanence. However, the sensitivity recorded with an angular step size of 5\u00b0 is best fitted by a |sin| function. Small deviations between sensitivity maxima at opposing angles (\u0394S \u2248 3% for the scissor and \u2248 5% for the parallelly canted sensor) may be attributed to rotation within the ambient magnetic field in the unshielded environment and the known dependence of sensitivity on a static bias field (cf. Figure <a data-track=\"click\" data-track-label=\"link\" data-track-action=\"figure anchor\" href=\"http:\/\/www.nature.com\/articles\/s41598-026-76696-2#Fig5\" rel=\"nofollow noopener\" target=\"_blank\">5<\/a>a, c).<\/p>\n","protected":false},"excerpt":{"rendered":"To verify that the intended magnetic anisotropies were successfully imprinted during layer growth, the integral magnetization of both&hellip;\n","protected":false},"author":2,"featured_media":657391,"comment_status":"","ping_status":"","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[7],"tags":[7795,2026,61,60,2027,248,82],"class_list":["post-657390","post","type-post","status-publish","format-standard","has-post-thumbnail","category-science","tag-engineering","tag-humanities-and-social-sciences","tag-ie","tag-ireland","tag-multidisciplinary","tag-physics","tag-science"],"_links":{"self":[{"href":"https:\/\/www.newsbeep.com\/ie\/wp-json\/wp\/v2\/posts\/657390","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.newsbeep.com\/ie\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.newsbeep.com\/ie\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.newsbeep.com\/ie\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/www.newsbeep.com\/ie\/wp-json\/wp\/v2\/comments?post=657390"}],"version-history":[{"count":0,"href":"https:\/\/www.newsbeep.com\/ie\/wp-json\/wp\/v2\/posts\/657390\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.newsbeep.com\/ie\/wp-json\/wp\/v2\/media\/657391"}],"wp:attachment":[{"href":"https:\/\/www.newsbeep.com\/ie\/wp-json\/wp\/v2\/media?parent=657390"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.newsbeep.com\/ie\/wp-json\/wp\/v2\/categories?post=657390"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.newsbeep.com\/ie\/wp-json\/wp\/v2\/tags?post=657390"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}