Timmis, A. et al. European society of cardiology: cardiovascular disease statistics 2021. Eur. Heart J. 43, 716–799 (2022).
Zrinscak, D., Lorenzon, L., Maselli, M. & Cianchetti, M. Soft robotics for physical simulators, artificial organs and implantable assistive devices. Prog. Biomed. Eng. 5, 012002 (2023).
Singh, M. et al. Hemodynamic evaluation of biomaterial-based surgery for tetralogy of Fallot using a biorobotic heart, in silico, and ovine models. Sci. Transl. Med. 16, eadk2936 (2024).
Omisore, O. M. et al. A review on flexible robotic systems for minimally invasive surgery. IEEE Trans. Syst., Man, Cybern. Syst. 52, 631–644 (2022).
Siontis, G. C. M. et al. Transcatheter aortic valve implantation vs. surgical aortic valve replacement for treatment of symptomatic severe aortic stenosis: an updated meta-analysis. Eur. Heart J. 40, 3143–3153 (2019).
Sunwoo, S.-H. et al. Soft bioelectronics for the management of cardiovascular diseases. Nat. Rev. Bioeng. 2, 8–24 (2024).
Friedman, P. et al. Performance and safety of the extravascular implantable cardioverter defibrillator through long-term follow-up: final results from the pivot al study. Circulation 151, 322–332 (2025).
Runciman, M., Darzi, A. & Mylonas, G. P. Soft robotics in minimally invasive surgery. Soft Robot. 6, 423–443 (2019).
Cianchetti, M., Laschi, C., Menciassi, A. & Dario, P. Biomedical applications of soft robotics. Nat. Rev. Mater. 3, 143–153 (2018).
Proietti, T. et al. Restoring arm function with a soft robotic wearable for individuals with amyotrophic lateral sclerosis. Sci. Transl. Med. 15, eadd1504 (2023).
Lee, H. C. et al. A fabrication strategy for millimeter-scale, self-sensing soft-rigid hybrid robots. Nat. Commun. 15, 8456 (2024).
Park, C., Ozturk, C. & Roche, E. T. Computational design of a soft robotic myocardium for biomimetic motion and function. Adv. Funct. Mater. 32, 2206734 (2022).
Roche, E. T. et al. Soft robotic sleeve supports heart function. Sci. Transl. Med. 9, eaaf3925 (2017).
Buckberg, G., Hoffman, J. I. E., Mahajan, A., Saleh, S. & Coghlan, C. Cardiac mechanics revisited. Circulation 118, 2571–2587 (2008).
Nagel, E. et al. Cardiac rotation and relaxation in patients with aortic valve stenosis. Eur. Heart J. 21, 582–589 (2000).
Weymann, A. et al. Artificial muscles and soft robotic devices for treatment of end-stage heart failure. Adv. Mater. 35, 2207390 (2023).
Tavlasoglu, M., Jahollari, A., Amrahov, A. & Sahin, M. A. An instrument facilitates mitral valve repair training at home. Eur. J. Cardio-Thorac. Surg. 41, 940–941 (2012).
Wang, D. D. et al. 3D printing, computational modeling, and artificial intelligence for structural heart disease. JACC Cardiovasc. Imaging 14, 41–60 (2021).
Leopaldi, A. M. et al. The dynamic cardiac biosimulator: a method for training physicians in beating-heart mitral valve repair procedures. J. Thorac. Cardiovasc. Surg. 155, 147–155 (2018).
Smooth-On. Ecoflex™ Series: super-soft, addition cure silicone rubbers. Product overview. smooth-on.com https://www.smooth-on.com/tb/files/ECOFLEX_SERIES_TB.pdf (2024).
Xavier, M. S., Fleming, A. J. & Yong, Y. K. Finite element modeling of soft fluidic actuators: overview and recent developments. Adv. Intell. Syst. 3, 2000187 (2021).
Gunduz, S., Albadawi, H. & Oklu, R. Robotic devices for minimally invasive endovascular interventions: a new dawn for interventional radiology. Adv. Intell. Syst. 3, 2000181 (2021).
Medrano-Gracia, P. et al. A computational atlas of normal coronary artery anatomy. EuroIntervention 12, 845–854 (2016).
Boufi, M. et al. Morphological analysis of healthy aortic arch. Eur. J. Vasc. Endovasc. Surg. 53, 663–670 (2017).
Hutchins, G. M., Miner, M. M. & Boitnott, J. K. Vessel caliber and branch-angle of human coronary artery branch-points. Circ. Res. 38, 572–576 (1976).
Rogatinsky, J. et al. A multifunctional soft robot for cardiac interventions. Sci. Adv. 9, eadi5559 (2023).
Gang, E. S. et al. Dynamically shaped magnetic fields: initial animal validation of a new remote electrophysiology catheter guidance and control system. Circ. Arrhythm. Electrophysiol. 4, 770–777 (2011).
Gu, H. et al. Self-folding soft-robotic chains with reconfigurable shapes and functionalities. Nat. Commun. 14, 1263 (2023).
Deng, T., Wang, H., Chen, W., Wang, X. & Pfeifer, R. Development of a new cable-driven soft robot for cardiac ablation. In 2013 IEEE International Conference on Robotics and Biomimetics (ROBIO) 728–733 (IEEE, 2013).
Nguyen, C. C. et al. Bidirectional soft robotic catheter for arrhythmia treatment. In 2022 International Conference on Robotics and Automation, 9579–9585 (IEEE, 2022).
Piskarev, Y. et al. A variable stiffness magnetic catheter made of a conductive phase-change polymer for minimally invasive surgery. Adv. Funct. Mater. 32, 2107662 (2022).
Mirzajani, H. & Kraft, M. Soft bioelectronics for heart monitoring. ACS Sens. 9, 4328–4363 (2024).
Rawish, E., Schmidt, T., Eitel, I. & Frerker, C. Current status of catheter-based mitral valve replacement. Curr. Cardiol. Rep. 23, 95 (2021).
Han, J. J., Acker, M. A. & Atluri, P. Left ventricular assist devices. Circulation 138, 2841–2851 (2018).
Zhao, C., Park, J., Root, S. E. & Bao, Z. Skin-inspired soft bioelectronic materials, devices and systems. Nat. Rev. Bioeng. 2, 671–690 (2024).
Qiu, R. et al. E-cardiac patch to sense and repair infarcted myocardium. Nat. Commun. 15, 4133 (2024).
Park, C. et al. An organosynthetic dynamic heart model with enhanced biomimicry guided by cardiac diffusion tensor imaging. Sci. Robot. 5, eaay9106 (2020).
Davies, J. et al. Soft robotic artificial left ventricle simulator capable of reproducing myocardial biomechanics. Sci. Robot. 9, eado4553 (2024).
Thompson, N. A., Shin, S., Kocheril, A. G., Hsiao-Wecksler, E. T. & Krishnan, G. Design and validation of a soft robotic simulator for transseptal puncture training. IEEE Trans. Biomed. Eng. 70, 3003–3014 (2023).
Zhou, Y. et al. Design and analysis of a novel bionic cardiac simulator. In 2018 IEEE International Conference on Information and Automation (ICIA), 1245–1250 (IEEE, 2018).
Park, C., Singh, M., Saeed, M. Y., Nguyen, C. T. & Roche, E. T. Biorobotic hybrid heart as a benchtop cardiac mitral valve simulator. Device 2, 100217 (2024).
Demeersseman, N. et al. Activation of a soft robotic left ventricular phantom embedded in a closed-loop cardiovascular simulator: a computational and experimental analysis. Cardiovasc. Eng. Technol. 16, 34–51 (2025).
Ueda, D., Suzumori, K., Nabae, H., Ishikawa, Y. & Oda, T. Soft robotic heart formed with a myocardial band for cardiac functions. Soft Robot. 12, 488–497 (2025).
Chamberlain, E. R. Cardiac surgical trainer and method for making same. US Patent 20020061503-A1 (2002).
Lorenzon, L. et al. Harnessing mechanical instabilities in the development of an efficient soft pump for an artificial heart ventricle simulator. IEEE/ASME Trans. Mechatron. 29, 936–946 (2024).
Gulbulak, U. & Ertas, A. Finite element driven design domain identification of a beating left ventricular simulator. Bioengineering 6, 83 (2019).
Singh, M. et al. Robotic right ventricle is a biohybrid platform that simulates right ventricular function in (patho)physiological conditions and intervention. Nat. Cardiovasc. Res. 2, 1310–1326 (2023).
Singh, M., Park, C. & Roche, E. T. Decellularization following fixation of explanted aortic valves as a strategy for preserving native mechanical properties and function. Front. Bioeng. Biotechnol. 9, 803183 (2021).
Yue, Z. et al. Kaempferol alleviates myocardial ischemia injury by reducing oxidative stress via the HDAC3-mediated Nrf2 signaling pathway. J. Adv. Res. 75, 755–764 (2025).
Hulsmans, M. et al. Recruited macrophages elicit atrial fibrillation. Science 381, 231–239 (2023).
Rosalia, L. et al. Soft robotic platform for progressive and reversible aortic constriction in a small-animal model. Sci. Robot. 9, eadj9769 (2024).
Rosalia, L. et al. A soft robotic sleeve mimicking the haemodynamics and biomechanics of left ventricular pressure overload and aortic stenosis. Nat. Biomed. Eng. 6, 1134–1147 (2022).
Rosalia, L. et al. Modulating cardiac hemodynamics using tunable soft robotic sleeves in a porcine model of HFpEF physiology for device testing applications. Adv. Funct. Mater. 34, 2310085 (2024).
Charles, C. J., Rademaker, M. T., Scott, N. J. A. & Richards, A. M. Large animal models of heart failure: reduced vs. preserved ejection fraction. Animals 10, 1906 (2020).
Rosalia, L. et al. Soft robotic patient-specific hydrodynamic model of aortic stenosis and ventricular remodeling. Sci. Robot. 8, eade2184 (2023).
Miyagi, C. et al. Large animal models of heart failure with preserved ejection fraction. Heart Fail. Rev. 27, 595–608 (2022).
Lang, R. M. et al. Recommendations for cardiac chamber quantification by echocardiography in adults: an update from the American Society of Echocardiography and the European Association of Cardiovascular Imaging. Eur. Heart J. Cardiovasc. Imaging 16, 233–271 (2015).
Dodge, J. T., Brown, B. G., Bolson, E. L. & Dodge, H. T. Lumen diameter of normal human coronary arteries. Influence of age, sex, anatomic variation, and left ventricular hypertrophy or dilation. Circulation 86, 232–246 (1992).
Zhang, Y., Liao, J., Chen, M., Li, X. & Jin, G. A multi-module soft robotic arm with soft actuator for minimally invasive surgery. Int. J. Med. Robot. Comput. Assist. Surg. 19, e2467 (2023).
Wang, H., Zhang, R., Chen, W., Wang, X. & Pfeifer, R. A cable-driven soft robot surgical system for cardiothoracic endoscopic surgery: preclinical tests in animals. Surg. Endosc. 31, 3152–3158 (2017).
Zhu, J. et al. Intelligent soft surgical robots for next-generation minimally invasive surgery. Adv. Intell. Syst. 3, 2100011 (2021).
Liu, X. Soft robot system for heart surgery. In 2020 IEEE International Conference on Artificial Intelligence and Information Systems (ICAIIS), 470–475 (IEEE, 2020).
Rus, D. & Tolley, M. T. Design, fabrication and control of soft robots. Nature 521, 467–475 (2015).
Hausladen, M. M. et al. Synthetic growth by self-lubricated photopolymerization and extrusion inspired by plants and fungi. Proc. Natl Acad. Sci. USA 119, e2201776119 (2022).
Hawkes, E. W., Blumenschein, L. H., Greer, J. D. & Okamura, A. M. A soft robot that navigates its environment through growth. Sci. Robot. 2, eaan3028 (2017).
Kim, N. G., Seo, D., Park, S. & Ryu, J. H. Self-retractable soft growing robots for reliable and fast retraction while preserving their inherent advantages. IEEE Robot. Autom. Lett. 9, 1082–1089 (2024).
Mao, L. et al. Magnetic steering continuum robot for transluminal procedures with programmable shape and functionalities. Nat. Commun. 15, 3759 (2024).
Morimoto, Y., Onoe, H. & Takeuchi, S. Biohybrid robot powered by an antagonistic pair of skeletal muscle tissues. Sci. Robot. 3, eaat4440 (2018).
Yang, B. et al. Reprogrammable soft actuation and shape-shifting via tensile jamming. Sci. Adv. 7, eabh2073 (2021).
Yun, G. et al. Electro-mechano responsive elastomers with self-tunable conductivity and stiffness. Sci. Adv. 9, eadf1141 (2023).
Kanagaratnam, P. et al. Experience of robotic catheter ablation in humans using a novel remotely steerable catheter sheath. J. Interv. Card. Electrophysiol. 21, 19–26 (2008).
Shaikh, Z., Eilenberg, M. & Cohen, T. The Amigo™ remote catheter system: from concept to bedside. J. Innov. Card. Rhythm Manag. 8, 2795–2802 (2017).
Phelan Iii, M. F., Tiryaki, M. E., Lazovic, J., Gilbert, H. & Sitti, M. Heat-mitigated design and Lorentz force-based steering of an MRI-driven microcatheter toward minimally invasive surgery. Adv. Sci. 9, 2105352 (2022).
Kim, Y., Parada, G. A., Liu, S. & Zhao, X. Ferromagnetic soft continuum robots. Sci. Robot. 4, eaax7329 (2019).
Tiryaki, M. E., Elmacıoğlu, Y. G. & Sitti, M. Magnetic guidewire steering at ultrahigh magnetic fields. Sci. Adv. 9, eadg6438 (2023).
Nguyen, C. C. et al. Development of a soft robotic catheter for vascular intervention surgery. Sens. Actuat. A Phys. 357, 114380 (2023).
Guan, F. et al. Iontronic tip-sensing guidewires. Nat. Biomed. Eng. https://doi.org/10.1038/s41551-025-01548-9 (2025).
Zhang, M. et al. A magnetically actuated microcatheter with soft rotatable tip for enhanced endovascular access and treatment efficiency. Sci. Adv. 11, eadv1682 (2025).
Rivkin, B. et al. Electronically integrated microcatheters based on self-assembling polymer films. Sci. Adv. 7, eabl5408 (2021).
Fan, J. et al. Magnetic fiber robots with multiscale functional structures at the distal end. Adv. Funct. Mater. 34, 2309424 (2024).
Han, M. et al. Catheter-integrated soft multilayer electronic arrays for multiplexed sensing and actuation during cardiac surgery. Nat. Biomed. Eng. 4, 997–1009 (2020).
Kashyap, V. et al. Multilayer fabrication of durable catheter-deployable soft robotic sensor arrays for efficient left atrial mapping. Sci. Adv. 6, eabc6800 (2020).
Hao, B. et al. Focused ultrasound enables selective actuation and Newton-level force output of untethered soft robots. Nat. Commun. 15, 5197 (2024).
Zheng, J., Qi, R., Dai, C., Li, G. & Sang, M. Enzyme catalysis biomotor engineering of neutrophils for nanodrug delivery and cell-based thrombolytic therapy. ACS Nano 16, 2330–2344 (2022).
Shao, J. et al. Erythrocyte membrane modified Janus polymeric motors for thrombus therapy. ACS Nano 12, 4877–4885 (2018).
Li, Z. et al. Untethered & stiffness-tunable ferromagnetic liquid robots for cleaning thrombus in complex blood vessels. Adv. Mater. 36, 2409142 (2024).
Wang, Q. et al. Untethered miniature robots for minimally invasive thrombus treatment: from bench to clinical trials. Innovation 6, 100874 (2025).
Lee, W., Nam, J., Kim, J., Jung, E. & Jang, G. Effective locomotion and precise unclogging motion of an untethered flexible-legged magnetic robot for vascular diseases. IEEE Trans. Ind. Electron. 65, 1388–1397 (2018).
van Vliet, G. M., Misra, S. & Venkiteswaran, V. K. A magnetically-actuated flexible capsule robot for untethered cardiovascular interventions. In 2022 IEEE 5th International Conference on Soft Robotics (RoboSoft), 583–588 (IEEE, 2022).
Zhang, W. et al. Amoeba-inspired magnetic venom microrobots. Small 19, 2207360 (2023).
Wang, B. et al. tPA-anchored nanorobots for in vivo arterial recanalization at submillimeter-scale segments. Sci. Adv. 10, eadk8970 (2024).
Wang, T. et al. Adaptive wireless millirobotic locomotion into distal vasculature. Nat. Commun. 13, 4465 (2022).
Ansari, M. et al. An experimental investigation on shape memory polymer and metallic stents under bending and radial compression. Eng. Res. Express 2, 045012 (2020).
Yasmin, F., Vafadar, A. & Tolouei-Rad, M. Application of additive manufacturing in the development of polymeric bioresorbable cardiovascular stents: a review. Adv. Mater. Technol. 10, 2400210 (2025).
Zong, J. et al. Advances in the development of biodegradable coronary stents: a translational perspective. Mater. Today Bio 16, 100368 (2022).
Herbert, R., Lim, H.-R., Rigo, B. & Yeo, W.-H. Fully implantable wireless batteryless vascular electronics with printed soft sensors for multiplex sensing of hemodynamics. Sci. Adv. 8, eabm1175 (2022).
Son, D. et al. Bioresorbable electronic stent integrated with therapeutic nanoparticles for endovascular diseases. ACS Nano 9, 5937–5946 (2015).
Gaudino, M. et al. Association of radial artery graft vs saphenous vein graft with long-term cardiovascular outcomes among patients undergoing coronary artery bypass grafting: a systematic review and meta-analysis. JAMA 324, 179–187 (2020).
Lu, D. et al. Bioresorbable wireless sensors as temporary implants for in vivo measurements of pressure. Adv. Funct. Mater. 30, 2003754 (2020).
Ouyang, H. et al. A bioresorbable dynamic pressure sensor for cardiovascular postoperative care. Adv. Mater. 33, 2102302 (2021).
Tang, C. et al. Unconstrained piezoelectric vascular electronics for wireless monitoring of hemodynamics and cardiovascular health. Small 20, 2304752 (2024).
Boutry, C. M. et al. Biodegradable and flexible arterial-pulse sensor for the wireless monitoring of blood flow. Nat. Biomed. Eng. 3, 47–57 (2019).
Liu, Z. et al. Electronic vascular conduit for in situ identification of hemadostenosis and thrombosis in small animals and nonhuman primates. Nat. Commun. 16, 2671 (2025).
Li, J. et al. Multifunctional artificial artery from direct 3D printing with built-in ferroelectricity and tissue-matching modulus for real-time sensing and occlusion monitoring. Adv. Funct. Mater. 30, 2002868 (2020).
Cheng, S. et al. Electronic blood vessel. Matter 3, 1664–1684 (2020).
Ma, Z. et al. Smart vascular grafts with integrated flow biosensors for hemodynamic real-time monitoring and vascular healthcare. ACS Nano 19, 7661–7676 (2025).
Park, K. et al. Resealable antithrombotic artificial vascular graft integrated with a self-healing blood flow sensor. ACS Nano 17, 7296–7310 (2023).
Sim, K. et al. An epicardial bioelectronic patch made from soft rubbery materials and capable of spatiotemporal mapping of electrophysiological activity. Nat. Electron. 3, 775–784 (2020).
Lee, W. et al. Nonthrombogenic, stretchable, active multielectrode array for electroanatomical mapping. Sci. Adv. 4, eaau2426 (2018).
Choi, S. et al. Highly conductive, stretchable and biocompatible Ag–Au core–sheath nanowire composite for wearable and implantable bioelectronics. Nat. Nanotechnol. 13, 1048–1056 (2018).
Park, J. et al. Electromechanical cardioplasty using a wrapped elasto-conductive epicardial mesh. Sci. Transl. Med. 8, 344ra386 (2016).
Zhang, L. et al. Skin-inspired, sensory robots for electronic implants. Nat. Commun. 15, 4777 (2024).
Wang, L. et al. Injectable and conductive cardiac patches repair infarcted myocardium in rats and minipigs. Nat. Biomed. Eng. 5, 1157–1173 (2021).
Pabari, P. A. et al. When is an optimization not an optimization? Evaluation of clinical implications of information content (signal-to-noise ratio) in optimization of cardiac resynchronization therapy, and how to measure and maximize it. Heart Fail. Rev. 16, 277–290 (2011).
Viventi, J. et al. A conformal, bio-interfaced class of silicon electronics for mapping cardiac electrophysiology. Sci. Transl. Med. 2, 24ra22 (2010).
Mulpuru, S. K., Madhavan, M., McLeod, C. J., Cha, Y.-M. & Friedman, P. A. Cardiac pacemakers: function, troubleshooting, and management: part 1 of a 2-part series. J. Am. Coll. Cardiol. 69, 189–210 (2017).
Choi, Y. S. et al. Fully implantable and bioresorbable cardiac pacemakers without leads or batteries. Nat. Biotechnol. 39, 1228–1238 (2021).
Choi, H. et al. Adhesive bioelectronics for sutureless epicardial interfacing. Nat. Electron. 6, 779–789 (2023).
Bolonduro, O. A. et al. An integrated optogenetic and bioelectronic platform for regulating cardiomyocyte function. Adv. Sci. 11, 2402236 (2024).
Mendez, K. L. et al. SmartSleeve: a sutureless, soft robotic epicardial device that enables switchable on-off drug delivery in response to epicardial ECG sensing. Device 2, 100419 (2024).
Bonnemain, J., del Nido, P. J. & Roche, E. T. Direct cardiac compression devices to augment heart biomechanics and function. Annu. Rev. Biomed. Eng. 24, 137–156 (2022).
Burkhoff, D., Sayer, G., Doshi, D. & Uriel, N. Hemodynamics of mechanical circulatory support. J. Am. Coll. Cardiol. 66, 2663–2674 (2015).
Almanza, M. et al. Feasibility of a dielectric elastomer augmented aorta. Adv. Sci. 8, 2001974 (2021).
Pirozzi, I. et al. Electrohydraulic vascular compression device (e-VaC) with integrated sensing and controls. Adv. Mater. Technol. 8, 2201196 (2023).
Abraham, W. T. et al. Ambulatory extra-aortic counterpulsation in patients with moderate to severe chronic heart failure. JACC Heart Fail. 2, 526–533 (2014).
Martinez, T. et al. A novel soft cardiac assist device based on a dielectric elastomer augmented aorta: an in vivo study. Bioeng. Transl. Med. 8, e10396 (2023).
Schulz, A. et al. Preliminary results from the C-Pulse® OPTIONS HF European Multicenter post-market study. Med. Sci. Monit. Basic Res. 22, 14–19 (2016).
Ji, A. et al. Development of a self-deploying extra-aortic compression device for medium-term hemodynamic stabilization: a feasibility study. Adv. Sci. 12, 2412120 (2025).
Kim, J., Lee, J., Song, S., Kang, S.-H. & Han, A. K. E-CAD: electroactive polymer-based cardiac assist device with low power consumption. Adv. Intell. Syst. 7, 2500076 (2025).
Phan, P. T. et al. Robotic cardiac compression device using artificial muscle filaments for the treatment of heart failure. Adv. Intell. Syst. 6, 2300464 (2024).
Saeed, M. Y. et al. Dynamic augmentation of left ventricle and mitral valve function with an implantable soft robotic device. JACC Basic Transl. Sci. 5, 229–242 (2020).
Payne, C. J. et al. Soft robotic ventricular assist device with septal bracing for therapy of heart failure. Sci. Robot. 2, eaan6736 (2017).
Vis, A. et al. The ongoing quest for the first total artificial heart as destination therapy. Nat. Rev. Cardiol. 19, 813–828 (2022).
Cohrs, N. H. et al. A soft total artificial heart—first concept evaluation on a hybrid mock circulation. Artif. Organs 41, 948–958 (2017).
Arfaee, M. et al. A soft robotic total artificial hybrid heart. Nat. Commun. 16, 5146 (2025).
Guex, L. G. et al. Increased longevity and pumping performance of an injection molded soft total artificial heart. Soft Robot. 8, 588–593 (2021).
Arfaee, M. et al. Toward developing a compact total artificial heart using a soft robotic fluidic transmission system. Sci. Adv. 11, eadv4854 (2025).
Wu, W. et al. On the understanding of dielectric elastomer and its application for all-soft artificial heart. Sci. Bull. 66, 981–990 (2021).
Yoo, J., Chung, G. & Park, Y. Bio-inspired, miniaturized magnetic heart valve system for superior performance cardiovascular simulator. Adv. Mater. 37, 2419504 (2025).
Brown, N. C., Ames, D. C. & Mueller, J. Multimaterial extrusion 3D printing printheads. Nat. Rev. Mater. 10, 807–825 (2025).
Zhou, L.-Y., Fu, J. & He, Y. A review of 3D printing technologies for soft polymer materials. Adv. Funct. Mater. 30, 2000187 (2020).
Sachyani Keneth, E., Kamyshny, A., Totaro, M., Beccai, L. & Magdassi, S. 3D printing materials for soft robotics. Adv. Mater. 33, 2003387 (2021).
Zhou, C. et al. Submillimeter fiber robots capable of decoupled macro-micro motion for endoluminal manipulation. Sci. Adv. 10, eadr6428 (2024).
Abdelaziz, M. E. M. K. et al. Fiberbots: robotic fibers for high-precision minimally invasive surgery. Sci. Adv. 10, eadj1984 (2024).
Dreyfus, R. et al. Dexterous helical magnetic robot for improved endovascular access. Sci. Robot. 9, eadh0298 (2024).
Yan, Y. et al. Magnetically assisted soft milli-tools for occluded lumen morphology detection. Sci. Adv. 9, eadi3979 (2023).
Li, S. et al. Recent progress in contact force sensing techniques for cardiovascular interventional procedures. Adv. Mater. https://doi.org/10.1002/adma.202513239 (2025).
Ren, B. et al. The critical technologies of vascular interventional robotic catheterization: a review. IEEE Sens. J. 23, 30051–30069 (2023).
Yuan, M. et al. Soft electronics for advanced infant monitoring. Mater. Today 75, 166–186 (2024).
Takakuwa, M. et al. Device integration technology for practical flexible electronics systems. Adv. Funct. Mater. https://doi.org/10.1002/adfm.202514330 (2025).
Nair, V. et al. Miniature battery-free bioelectronics. Science 382, eabn4732 (2023).
Liu, Z. et al. A self-powered intracardiac pacemaker in swine model. Nat. Commun. 15, 507 (2024).
Deng, J. et al. A bioadhesive pacing lead for atraumatic cardiac monitoring and stimulation in rodent and porcine models. Sci. Transl. Med. 16, eado9003 (2024).
Roels, E. et al. Processing of self-healing polymers for soft robotics. Adv. Mater. 34, 2104798 (2022).
Fauvre, L., Portinha, D., Fleury, E. & Ganachaud, F. Thermoplastic silicone elastomers as materials exhibiting high mechanical properties and/or self-healing propensity. J. Adhes. Sci. Technol. 35, 2723–2735 (2021).
Mariello, M., Kim, K., Wu, K., Lacour, S. P. & Leterrier, Y. Recent advances in encapsulation of flexible bioelectronic implants: materials, technologies, and characterization methods. Adv. Mater. 34, 2201129 (2022).
Jupiter Endovascular. Press release. Jupiter endovascular closes oversubscribed series B financing, surpassing $40 million target. jupiterendo.com https://jupiterendo.com/jupiter-endovascular-closes-oversubscribed-series-b-financing-surpassing-40-million-target/ (2025).
Stereotaxis. Press release. Stereotaxis receives U.S. FDA clearance for MAGiC Sweep catheter. stereotaxis.com https://ir.stereotaxis.com/news-releases/news-release-details/stereotaxis-receives-us-fda-clearance-magic-sweep-catheter (2025).
Cardiovascularnews. CorPath GRX robotic system receives FDA 510(k) clearance. cardiovascularnews.com https://cardiovascularnews.com/corpath-grx-robotic-systems-receives-fda-510k-clearance/ (2016).
Johnson & Johnson MedTech. Press release. Biosense Webster launches the OCTARAY™ mapping catheter with TRUEref™ technology. jnjmedtech.com https://www.jnjmedtech.com/en-US/news-events/biosense-webster-launches-octaray-mapping-catheter-trueref-technology (2022).
Johnson & Johnson MedTech. Press release. The evolving landscape of atrial fibrillation ablation: VARIPULSE™ launches in European hospitals. jnjmedtech.com https://www.jnjmedtech.com/en-EMEA/news-events/evolving-landscape-atrial-fibrillation-ablation-varipulse-launches-european-hospitals (2024).
Medtronic. Press release. Medtronic reports third quarter fiscal 2024 financial results. medtronic.com https://news.medtronic.com/2024-02-20-Medtronic-reports-third-quarter-fiscal-2024-financial-results (2024).
Boston Scientific. Press release. Boston Scientific launches next generation of cardiac mapping for the FARAPULSE™ pulsed field ablation system. bostonscientific.com https://news.bostonscientific.com/2024-10-18-Boston-Scientific-Launches-Next-Generation-of-Cardiac-Mapping-for-the-FARAPULSE-TM-Pulsed-Field-Ablation-System (2024).
Stereotaxis. Press release. GenesisX robotic magnetic navigation system receives U.S. FDA clearance. stereotaxis.com https://ir.stereotaxis.com/news-releases/news-release-details/genesisx-robotic-magnetic-navigation-system-receives-us-fda (2025).
Stereotaxis. Press release. Stereotaxis earns FDA clearance and announces U.S. launch of genesis robotic magnetic navigation system. stereotaxis.com https://ir.stereotaxis.com/news-releases/news-release-details/stereotaxis-earns-fda-clearance-and-announces-us-launch-genesis (2020).
Baue, A. E., Tragus, E. T., Anstadt, G. L. & Blakemore, W. S. Mechanical ventricular assistance in man. Circulation 37, II-33–II-36 (1968).
PRWeb. German start-up AdjuCor marks milestone with successful first-in-human implantations of reBEAT system. prweb.com https://www.prweb.com/releases/german-start-up-adjucor-marks-milestone-with-successful-first-in-human-implantations-of-rebeat-system-301962827.html (2023).
Yu, C. et al. Chronological adhesive cardiac patch for synchronous mechanophysiological monitoring and electrocoupling therapy. Nat. Commun. 14, 6226 (2023).
Qu, J. et al. Advanced flexible sensing technologies for soft robots. Adv. Funct. Mater. 34, 2401311 (2024).
Hegde, C. et al. Sensing in soft robotics. ACS Nano 17, 15277–15307 (2023).
Liu, L. et al. Recent advances in flexible temperature sensors: materials, mechanism, fabrication, and applications. Adv. Sci. 11, 2405003 (2024).
Corsi, M. et al. Bioresorbable nanostructured chemical sensor for monitoring of pH level in vivo. Adv. Sci. 9, 2202062 (2022).