{"id":290215,"date":"2025-11-14T01:43:07","date_gmt":"2025-11-14T01:43:07","guid":{"rendered":"https:\/\/www.newsbeep.com\/us\/290215\/"},"modified":"2025-11-14T01:43:07","modified_gmt":"2025-11-14T01:43:07","slug":"first-high-precision-measurement-of-potential-dynamics","status":"publish","type":"post","link":"https:\/\/www.newsbeep.com\/us\/290215\/","title":{"rendered":"First high-precision measurement of potential dynamics"},"content":{"rendered":"<p>            <img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/www.newsbeep.com\/us\/wp-content\/uploads\/2025\/11\/first-high-precision-m.jpg\" alt=\"First high-precision measurement of potential dynamics inside reactor-grade fusion plasma\" title=\"Variation of beam shape inside the multistage accelerator. (a) Beam trajectory at low beam current and (b) beam expansion at high beam current. (c) In the present study, optimization of the electrode voltages enabled both acceleration and focusing of the beam, resulting in a higher beam current. Credit: National Institute for Fusion Science\" width=\"800\" height=\"304\"\/><\/p>\n<p>                Variation of beam shape inside the multistage accelerator. (a) Beam trajectory at low beam current and (b) beam expansion at high beam current. (c) In the present study, optimization of the electrode voltages enabled both acceleration and focusing of the beam, resulting in a higher beam current. Credit: National Institute for Fusion Science<\/p>\n<p>Nuclear fusion, which operates on the same principle that powers the sun, is expected to become a sustainable energy source for the future. To achieve fusion power generation, it is essential to confine plasma at temperatures exceeding one hundred million degrees using a magnetic field and to maintain this high-energy state stably.<\/p>\n<p>A key factor in accomplishing this is the <a href=\"https:\/\/phys.org\/tags\/electric+potential\/\" rel=\"tag nofollow noopener\" class=\"textTag\" target=\"_blank\">electric potential<\/a> inside the plasma. This potential governs the transport of particles and energy within the plasma and plays a crucial role in establishing a state in which energy is effectively confined and prevented from escaping. Therefore, accurately measuring the internal plasma potential is essential for improving the performance of future fusion reactors.<\/p>\n<p>A non-contact diagnostic technique called the heavy ion beam probe (HIBP) is used to measure plasma potential directly. In this method, negatively charged <a href=\"https:\/\/phys.org\/tags\/gold+ions\/\" rel=\"tag nofollow noopener\" class=\"textTag\" target=\"_blank\">gold ions<\/a> (Au\u207b) are accelerated and injected into the plasma.<\/p>\n<p>By detecting how their charge state changes through interactions with the plasma, the electric potential inside the plasma can be inferred with high sensitivity. However, obtaining high-precision signals requires a strong and stable ion beam.<\/p>\n<p>Although advances in negative ion sources have increased the available beam current, efficiently transporting and injecting high-current beams into the accelerator has remained difficult, limiting the achievable diagnostic precision.<\/p>\n<p>How the HIBP system measures plasma<\/p>\n<p>In the Large Helical Device (LHD), the HIBP system has been developed to measure electric potential in plasmas.<\/p>\n<p>            <img decoding=\"async\" src=\"https:\/\/www.newsbeep.com\/us\/wp-content\/uploads\/2025\/11\/first-high-precision-m-1.jpg\" alt=\"First high-precision measurement of potential dynamics inside reactor-grade fusion plasma\" title=\"The Large Helical Device (LHD) and the heavy ion beam probe (HIBP) system. The inset on the left shows an enlarged view of the section from the negative ion source to the injection side of the tandem accelerator. Credit: National Institute for Fusion Science\"\/><\/p>\n<p>                The Large Helical Device (LHD) and the heavy ion beam probe (HIBP) system. The inset on the left shows an enlarged view of the section from the negative ion source to the injection side of the tandem accelerator. Credit: National Institute for Fusion Science<\/p>\n<p>In this system, a gold negative ion (Au\u207b) beam is injected into a tandem accelerator, converted into a gold positive ion (Au\u207a) beam, and further accelerated up to 6 mega\u2013electron volts (MeV) at the accelerator&#8217;s exit before being injected into the plasma.<\/p>\n<p>The beam that becomes Au\u00b2\u207a through collisions with the plasma passes through the magnetized plasma, and by measuring the energy difference between the incident Au\u207a beam and the Au\u00b2\u207a beam after it traverses the plasma, the electric potential at the position where Au\u00b2\u207a was produced can be determined.<\/p>\n<p>To obtain a clear and precise potential signal, a higher injection current into the plasma is required.<\/p>\n<p>Although the output current of the Au\u207b ion source had been successfully increased, the injection beam current into the tandem accelerator could not be increased in direct proportion, which remained a significant challenge.<\/p>\n<p>                <img decoding=\"async\" src=\"https:\/\/www.newsbeep.com\/us\/wp-content\/uploads\/2025\/11\/first-high-precision-m-2.jpg\" alt=\"First high-precision measurement of potential dynamics inside reactor-grade fusion plasma\"\/><\/p>\n<p>                    Beam transmission map as a function of electrode voltages V\u2082 and V\u2083 in the multistage accelerator. The blue circle indicates the voltage setting before optimization. By optimizing V\u2082 and V\u2083, an increase in the transmitted negative ion beam current can be expected. Credit: National Institute for Fusion Science<\/p>\n<p>                <img decoding=\"async\" src=\"https:\/\/www.newsbeep.com\/us\/wp-content\/uploads\/2025\/11\/first-high-precision-m-3.jpg\" alt=\"First high-precision measurement of potential dynamics inside reactor-grade fusion plasma\"\/><\/p>\n<p>                    Variation of the plasma potential profile associated with changes in the plasma state. The horizontal axis represents the plasma radius (r\/a = 0 corresponds to the plasma center, and r\/a = 1 to the plasma edge). Positive and negative potential changes, as well as variations in the profile shape, were clearly observed. Credit: National Institute for Fusion Science<\/p>\n<p>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\tSolving the beam transport bottleneck<\/p>\n<p>To identify the cause of this limitation, a research team analyzed the heavy-ion beam transport efficiency on the low-energy side\u2014from the negative ion source to the entrance of the tandem accelerator\u2014using the ion-beam transport simulation code IGUN. The work is <a href=\"https:\/\/iopscience.iop.org\/article\/10.1088\/1741-4326\/ae0da1\" target=\"_blank\" rel=\"nofollow noopener\">published<\/a> in the journal Nuclear Fusion.<\/p>\n<p>The simulations revealed that when the Au\u207b beam current is below 10 microamperes (\u00b5A), the beam can pass through the entrance slit during the acceleration. However, at higher beam currents, the beam expands due to the space-charge effect, resulting in significant beam loss before entering the tandem accelerator.<\/p>\n<p>For heavy-ion beams such as gold, this space-charge-induced limitation becomes particularly pronounced even if the output current from the negative ion source is increased.<\/p>\n<p>To improve beam transport efficiency, the team proposed using the multistage accelerator located between the ion source and the tandem accelerator, not only for acceleration but also as an electrostatic lens by optimizing its voltage distribution.<\/p>\n<p>Numerical simulations demonstrated that by optimizing the voltage allocation of the multistage electrodes, a high-transmission region exceeding 95% could be achieved, significantly enhancing the beam transport efficiency compared with the conventional voltage configuration.<\/p>\n<p>Subsequent plasma experiments confirmed the validity of this approach, showing that the Au\u207b beam current injected into the accelerator increased by a factor of two to three.<\/p>\n<p class=\"mb-3\">\n        Discover the latest in science, tech, and space with over 100,000 subscribers who rely on Phys.org for daily insights.<br \/>\n        Sign up for our <a href=\"https:\/\/sciencex.com\/help\/newsletter\/\" target=\"_blank\" rel=\"nofollow noopener\">free newsletter<\/a> and get updates on breakthroughs,<br \/>\n        innovations, and research that matter\u2014daily or weekly.\n    <\/p>\n<p>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\tExpanding plasma diagnostics and future impact<\/p>\n<p>As the Au\u207b beam current increased, the corresponding Au\u207a beam injected into the plasma also increased, thereby expanding the measurable range of plasma potential in the LHD up to a line-averaged electron density of 1.75\u00d710\u00b9\u2079 m\u207b\u00b3.<\/p>\n<p>The enhanced signal clarity enabled the detection of temporal transitions in the internal plasma potential distribution associated with changes in the plasma confinement state. At t = 4.0 s, the plasma was sustained by electron cyclotron heating; at t = 6.1 s, 0.1 s after the heating was turned off; and at t = 7.0 s, by 180 keV neutral beam injection.<\/p>\n<p>The results revealed a rapid overall decrease in plasma potential immediately after the termination of electron heating, followed by a gradual flattening of the potential profile. Because variations in plasma potential strongly influence plasma confinement performance, these <a href=\"https:\/\/phys.org\/tags\/experimental+data\/\" rel=\"tag nofollow noopener\" class=\"textTag\" target=\"_blank\">experimental data<\/a> are indispensable for improving predictive models of plasma behavior and for establishing new confinement frameworks in fusion research.<\/p>\n<p>The method developed in this study provides a practical and compact solution for optimizing heavy ion beam transport and can be extended to other diagnostic systems and <a href=\"https:\/\/phys.org\/tags\/accelerator\/\" rel=\"tag nofollow noopener\" class=\"textTag\" target=\"_blank\">accelerator<\/a> applications that require high-intensity beams.<\/p>\n<p>Furthermore, achieving high-precision and reproducible measurements of the internal potential structure in reactor-grade fusion plasmas is extremely important as a fundamental database for future research on <a href=\"https:\/\/phys.org\/tags\/plasma\/\" rel=\"tag nofollow noopener\" class=\"textTag\" target=\"_blank\">plasma<\/a> control and reactor design.<\/p>\n<p>More information:<br \/>\n\t\t\t\t\t\t\t\t\t\t\t\tM. Nishiura et al, Enhanced beam transport via space charge mitigation in a multistage accelerator for fusion plasma diagnostics, Nuclear Fusion (2025). <a data-doi=\"1\" href=\"https:\/\/dx.doi.org\/10.1088\/1741-4326\/ae0da1\" target=\"_blank\" rel=\"nofollow noopener\">DOI: 10.1088\/1741-4326\/ae0da1<\/a><\/p>\n<p>\n\t\t\t\t\t\t\t\t\t\t\t\t\tProvided by<br \/>\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<a href=\"https:\/\/phys.org\/partners\/national-institutes-of-natural-sciences\/\" rel=\"nofollow noopener\" target=\"_blank\">National Institutes of Natural Sciences<\/a><br \/>\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<a class=\"icon_open\" href=\"https:\/\/www.nins.jp\/en\/\" target=\"_blank\" rel=\"nofollow noopener\"><\/p>\n<p>\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/a>\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/p>\n<p>\n\t\t\t\t\t\t\t\t\t\t\t\tCitation:<br \/>\n\t\t\t\t\t\t\t\t\t\t\t\tReactor-grade fusion plasma: First high-precision measurement of potential dynamics (2025, November 13)<br \/>\n\t\t\t\t\t\t\t\t\t\t\t\tretrieved 13 November 2025<br \/>\n\t\t\t\t\t\t\t\t\t\t\t\tfrom https:\/\/phys.org\/news\/2025-11-reactor-grade-fusion-plasma-high.html\n\t\t\t\t\t\t\t\t\t\t\t <\/p>\n<p>\n\t\t\t\t\t\t\t\t\t\t\t This document is subject to copyright. Apart from any fair dealing for the purpose of private study or research, no<br \/>\n\t\t\t\t\t\t\t\t\t\t\t part may be reproduced without the written permission. The content is provided for information purposes only.\n\t\t\t\t\t\t\t\t\t\t\t <\/p>\n","protected":false},"excerpt":{"rendered":"Variation of beam shape inside the multistage accelerator. (a) Beam trajectory at low beam current and (b) beam&hellip;\n","protected":false},"author":2,"featured_media":290216,"comment_status":"","ping_status":"","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[49],"tags":[9151,13515,199,13513,79,13514,74,10353],"class_list":{"0":"post-290215","1":"post","2":"type-post","3":"status-publish","4":"format-standard","5":"has-post-thumbnail","7":"category-physics","8":"tag-materials","9":"tag-nanotech","10":"tag-physics","11":"tag-physics-news","12":"tag-science","13":"tag-science-news","14":"tag-technology","15":"tag-technology-news"},"_links":{"self":[{"href":"https:\/\/www.newsbeep.com\/us\/wp-json\/wp\/v2\/posts\/290215","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.newsbeep.com\/us\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.newsbeep.com\/us\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.newsbeep.com\/us\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/www.newsbeep.com\/us\/wp-json\/wp\/v2\/comments?post=290215"}],"version-history":[{"count":0,"href":"https:\/\/www.newsbeep.com\/us\/wp-json\/wp\/v2\/posts\/290215\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.newsbeep.com\/us\/wp-json\/wp\/v2\/media\/290216"}],"wp:attachment":[{"href":"https:\/\/www.newsbeep.com\/us\/wp-json\/wp\/v2\/media?parent=290215"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.newsbeep.com\/us\/wp-json\/wp\/v2\/categories?post=290215"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.newsbeep.com\/us\/wp-json\/wp\/v2\/tags?post=290215"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}